Sound

Page 17 highlights

Performance Data Air 16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit 16AJL- Model Numbers ID Coil ID Air Mover Stage Net Sensible BTU/H [kW] AHRI Cooling Performance 80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Net AHRI Ratings Latent BTU/H [kW] Total Capacity BTU/H [kW] SEER EER Indoor Airflow CFM [L/s] Rev. 5/8/2012 RGRM-12?RAJ? 1 30400 [8.9] 14600 [4.3] 1225 [578] 56000 [16.4] 15.5 11.5 2 39200 [11.5] 16800 [4.9] 1625 [767] RCFL-H*6024 RGTM-07?RBG? RGTM-09?ZAJ? RGTM-10?RBJ? 1 31600 [9.3] 13900 [4.1] 1325 [625] 56500 [16.6] 15 11.5 2 40300 [11.8] 16200 [4.7] 1675 [790] 1 31200 [9.1] 14300 [4.2] 1250 [590] 56000 [16.4] 15.5 11.5 2 39200 [11.5] 16800 [4.9] 1600 [755] 1 31300 [9.2] 14200 [4.2] 1275 [602] 56500 [16.6] 15.5 11.5 2 40300 [11.8] 16200 [4.7] 1675 [790] ROLA-070E04 ROLA-115E05 1 30400 [8.9] 14600 [4.3] 1175 [554] 56000 [16.4] 15.5 11.5 2 39200 [11.5] 16800 [4.9] 1600 [755] 1 30400 [8.9] 14600 [4.3] 1200 [566] 56500 [16.6] 15.5 11.5 2 39700 [11.6] 16800 [4.9] 1600 [755] RCFL-H*6024+RXMD-C04 Coil Only RGFE-09?ZCM? 1 29900 [8.8] 14600 [4.3] 1200 [566] 56500 [16.6] 14 11.5 2 39700 [11.6] 16800 [4.9] 1600 [755] 1 30400 [8.9] 14600 [4.3] 1200 [566] 56000 [16.4] 15 11 2 39200 [11.5] 16800 [4.9] 1600 [755] RGFE-10?ZCM? 1 30400 [8.9] 14600 [4.3] 1225 [578] 56000 [16.4] 15 11 2 39200 [11.5] 16800 [4.9] 1600 [755] RGFE-12?RCM? 1 30400 [8.9] 14600 [4.3] 1225 [578] 56000 [16.4] 15.5 11.5 2 39200 [11.5] 16800 [4.9] 1625 [767] 1 30400 [8.9] 14600 [4.3] 1200 [566] RGFG-09?ZCM? 56000 [16.4] 15 11 2 39200 [11.5] 16800 [4.9] 1600 [755] 60 1 30400 [8.9] 14600 [4.3] 1200 [566] RGFG-10?ZCM? 56500 [16.6] 15 11 2 40100 [11.7] 16400 [4.8] 1650 [779] RGFG-12?RCM? 1 30400 [8.9] 14600 [4.3] 1225 [578] 56000 [16.4] 15.5 11.5 2 39200 [11.5] 16800 [4.9] 1625 [767] RCFN-H*6024 RGGE-09?ZCM? RGGE-10?ZCM? 1 30400 [8.9] 14600 [4.3] 1225 [578] 56000 [16.4] 15.5 11.5 2 39200 [11.5] 16800 [4.9] 1600 [755] 1 30400 [8.9] 14600 [4.3] 1200 [566] 56000 [16.4] 15.5 11.5 2 39200 [11.5] 16800 [4.9] 1600 [755] RGGE-12?RCM? RGJF-09?ZCM? RGJF-10?ZCM? 1 30400 [8.9] 14600 [4.3] 1200 [566] 56500 [16.6] 15.5 11.5 2 39700 [11.6] 16800 [4.9] 1575 [743] 1 30400 [8.9] 14600 [4.3] 1225 [578] 56000 [16.4] 15.5 11.5 2 39200 [11.5] 16800 [4.9] 1600 [755] 1 30400 [8.9] 14600 [4.3] 1200 [566] 56000 [16.4] 15.5 11.5 2 39200 [11.5] 16800 [4.9] 1600 [755] RGJF-12?RCM? RGLE-07?BRQ? 1 30400 [8.9] 14600 [4.3] 1200 [566] 56500 [16.6] 15.5 11.5 2 39700 [11.6] 16800 [4.9] 1575 [743] 1 30400 [8.9] 14600 [4.3] 1225 [578] 56500 [16.6] 15.5 11.5 2 39700 [11.6] 16800 [4.9] 1600 [755] 1 RGLE-10?BRM? 2 1 RGLE-12?ARM? 2 ➀ Highest sales volume tested combination required by D.O.E. test procedures. 30400 [8.9] 14600 [4.3] 1200 [566] 56500 [16.6] 16 12 39700 [11.6] 16800 [4.9] 1600 [755] 30400 [8.9] 14600 [4.3] 1225 [578] 56500 [16.6] 16 12 39700 [11.6] 16800 [4.9] 1600 [755] Sound Rating dB 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 0 77 [ ] Designates Metric Conversions 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Air
Performance Data
16AJL Series
17
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
60
RCFL-H*6024
RGRM-12?RAJ?
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15.5
11.5
1225 [578]
0
2
39200 [11.5]
16800 [4.9]
1625 [767]
77
RGTM-07?RBG?
1
31600
[9.3]
13900 [4.1]
56500 [16.6]
15
11.5
1325 [625]
0
2
40300 [11.8]
16200 [4.7]
1675 [790]
77
RGTM-09?ZAJ?
1
31200
[9.1]
14300 [4.2]
56000 [16.4]
15.5
11.5
1250 [590]
0
2
39200 [11.5]
16800 [4.9]
1600 [755]
77
RGTM-10?RBJ?
1
31300
[9.2]
14200 [4.2]
56500 [16.6]
15.5
11.5
1275 [602]
0
2
40300 [11.8]
16200 [4.7]
1675 [790]
77
ROLA-070E04
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15.5
11.5
1175 [554]
0
2
39200 [11.5]
16800 [4.9]
1600 [755]
77
ROLA-115E05
1
30400
[8.9]
14600 [4.3]
56500 [16.6]
15.5
11.5
1200 [566]
0
2
39700 [11.6]
16800 [4.9]
1600 [755]
77
RCFL-H*6024+RXMD-C04
Coil Only
1
29900
[8.8]
14600 [4.3]
56500 [16.6]
14
11.5
1200 [566]
0
2
39700 [11.6]
16800 [4.9]
1600 [755]
77
RCFN-H*6024
RGFE-09?ZCM?
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15
11
1200 [566]
0
2
39200 [11.5]
16800 [4.9]
1600 [755]
77
RGFE-10?ZCM?
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15
11
1225 [578]
0
2
39200 [11.5]
16800 [4.9]
1600 [755]
77
RGFE-12?RCM?
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15.5
11.5
1225 [578]
0
2
39200 [11.5]
16800 [4.9]
1625 [767]
77
RGFG-09?ZCM?
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15
11
1200 [566]
0
2
39200 [11.5]
16800 [4.9]
1600 [755]
77
RGFG-10?ZCM?
1
30400
[8.9]
14600 [4.3]
56500 [16.6]
15
11
1200 [566]
0
2
40100 [11.7]
16400 [4.8]
1650 [779]
77
RGFG-12?RCM?
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15.5
11.5
1225 [578]
0
2
39200 [11.5]
16800 [4.9]
1625 [767]
77
RGGE-09?ZCM?
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15.5
11.5
1225 [578]
0
2
39200 [11.5]
16800 [4.9]
1600 [755]
77
RGGE-10?ZCM?
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15.5
11.5
1200 [566]
0
2
39200 [11.5]
16800 [4.9]
1600 [755]
77
RGGE-12?RCM?
1
30400
[8.9]
14600 [4.3]
56500 [16.6]
15.5
11.5
1200 [566]
0
2
39700 [11.6]
16800 [4.9]
1575 [743]
77
RGJF-09?ZCM?
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15.5
11.5
1225 [578]
0
2
39200 [11.5]
16800 [4.9]
1600 [755]
77
RGJF-10?ZCM?
1
30400
[8.9]
14600 [4.3]
56000 [16.4]
15.5
11.5
1200 [566]
0
2
39200 [11.5]
16800 [4.9]
1600 [755]
77
RGJF-12?RCM?
1
30400
[8.9]
14600 [4.3]
56500 [16.6]
15.5
11.5
1200 [566]
0
2
39700 [11.6]
16800 [4.9]
1575 [743]
77
RGLE-07?BRQ?
1
30400
[8.9]
14600 [4.3]
56500 [16.6]
15.5
11.5
1225 [578]
0
2
39700 [11.6]
16800 [4.9]
1600 [755]
77
RGLE-10?BRM?
1
30400
[8.9]
14600 [4.3]
56500 [16.6]
16
12
1200 [566]
0
2
39700 [11.6]
16800 [4.9]
1600 [755]
77
RGLE-12?ARM?
1
30400
[8.9]
14600 [4.3]
56500 [16.6]
16
12
1225 [578]
0
2
39700 [11.6]
16800 [4.9]
1600 [755]
77
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures.
[
] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling