Rheem 16AJL Specifications - Page 5

°F [26.5°C] / 67°F [19.5°C] WB Indoor Air

Page 5 highlights

Performance Data Air 16AJL Series Performance Data @ AHRI Standard Conditions-Cooling Outdoor Unit 16AJL- Model Numbers ID Coil ID Air Mover Stage Net Sensible BTU/H [kW] AHRI Cooling Performance 80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air 95°F [35°C] DB Outdoor Air Net AHRI Ratings Latent BTU/H [kW] Total Capacity BTU/H [kW] SEER EER Indoor Airflow CFM [L/s] Rev. 5/8/2012 RGFE-06?MCK? 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] RGFG-06?MCK? RGGE-07?MCK? RGJF-07?MCK? 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] RCFL-H*2621 RGLE-07?AMK? RGPE-05?BMK? 1 15100 [4.4] 6700 [2.0] 600 [283] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14900 [4.4] 6700 [2.0] 575 [271] RGRM-04?MAE? 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] ROCA-070E03 1 15100 [4.4] 6700 [2.0] 600 [283] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] ROLA-070E03 RCFL-H*2621+RXMD-C04 Coil Only RGFE-06?MCK? 024 RGFG-06?MCK? RGGE-07?MCK? 1 15100 [4.4] 6700 [2.0] 600 [283] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14000 [4.1] 6800 [2.0] 525 [248] 24800 [7.3] 14.5 12 2 17500 [5.1] 7300 [2.1] 700 [330] 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] RCFN-H*2417 RGJF-07?MCK? RGLE-07?AMK? 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 15100 [4.4] 6700 [2.0] 600 [283] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] RGPE-05?BMK? 1 14900 [4.4] 6700 [2.0] 575 [271] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14900 [4.4] 6700 [2.0] 575 [271] RGRM-04?MAE? 25600 [7.5] 16 13 2 18600 [5.4] 7000 [2.1] 800 [378] ROCA-070E03 1 15100 [4.4] 6700 [2.0] 600 [283] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] ROLA-070E03 RCFN-H*2417+RXMD-C04 Coil Only 1 15100 [4.4] 6700 [2.0] 600 [283] 25800 [7.6] 16 13 2 18800 [5.5] 7000 [2.1] 800 [378] 1 14000 [4.1] 6800 [2.0] 525 [248] 24800 [7.3] 14.5 12 2 17500 [5.1] 7300 [2.1] 700 [330] 1 RGFE-06?MCK? 2 RCFN-H*2421 1 RGFG-06?MCK? 2 ➀ Highest sales volume tested combination required by D.O.E. test procedures. 14900 [4.4] 18800 [5.5] 14900 [4.4] 18800 [5.5] 6700 [2.0] 7000 [2.1] 6700 [2.0] 7000 [2.1] 25800 [7.6] 25800 [7.6] 575 [271] 16 13 800 [378] 575 [271] 16 13 800 [378] Sound Rating dB 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 0 74 [ ] Designates Metric Conversions 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Air
Performance Data
16AJL Series
5
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil
ID Air Mover
Total Capacity
BTU/H [kW]
SEER
EER
024
RCFL-H*2621
RGFE-06?MCK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGFG-06?MCK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGGE-07?MCK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGJF-07?MCK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGLE-07?AMK?
1
15100 [4.4]
6700 [2.0]
25800 [7.6]
16
13
600 [283]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGPE-05?BMK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGRM-04?MAE?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
ROCA-070E03
1
15100 [4.4]
6700 [2.0]
25800 [7.6]
16
13
600 [283]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
ROLA-070E03
1
15100 [4.4]
6700 [2.0]
25800 [7.6]
16
13
600 [283]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RCFL-H*2621+RXMD-C04
Coil Only
1
14000 [4.1]
6800 [2.0]
24800 [7.3]
14.5
12
525 [248]
0
2
17500 [5.1]
7300 [2.1]
700 [330]
74
RCFN-H*2417
RGFE-06?MCK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGFG-06?MCK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGGE-07?MCK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGJF-07?MCK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGLE-07?AMK?
1
15100 [4.4]
6700 [2.0]
25800 [7.6]
16
13
600 [283]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGPE-05?BMK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGRM-04?MAE?
1
14900 [4.4]
6700 [2.0]
25600 [7.5]
16
13
575 [271]
0
2
18600 [5.4]
7000 [2.1]
800 [378]
74
ROCA-070E03
1
15100 [4.4]
6700 [2.0]
25800 [7.6]
16
13
600 [283]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
ROLA-070E03
1
15100 [4.4]
6700 [2.0]
25800 [7.6]
16
13
600 [283]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RCFN-H*2417+RXMD-C04
Coil Only
1
14000 [4.1]
6800 [2.0]
24800 [7.3]
14.5
12
525 [248]
0
2
17500 [5.1]
7300 [2.1]
700 [330]
74
RCFN-H*2421
RGFE-06?MCK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
RGFG-06?MCK?
1
14900 [4.4]
6700 [2.0]
25800 [7.6]
16
13
575 [271]
0
2
18800 [5.5]
7000 [2.1]
800 [378]
74
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures.
[
] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling