Rheem H95 Direct Vent Indoor Series Brochure - Page 3

Superior Construction and Reliability - tankless

Page 3 highlights

Superior Construction and Reliability Air Intake (PVC Venting) Exhaust (PVC Venting) 1 2 7 8 6 3 5 4 9 10 Indoor Direct Vent 1 Stainless Steel Secondary Heat Exchanger 2 All-Copper Primary Heat Exchanger 3 Over Heat Film Wrap 4 Electronic Spark Ignition 5 199,900 Btu/h Modulating Burner 6 Electronic Control Board 7 Condensate Reservoir 8 Variable Speed Fan 9 Water Flow Control System 10 Modulating Gas Valve Condensate Neutralizer Discharge Outlet 3/4" Hot Water Outlet External Connection for Remote Control Cable 3/4" Cold 3/4" Gas Water Connection Inlet 1 2 7 8 6 3 5 4 9 10 Outdoor 1 Stainless Steel Secondary Heat Exchanger 2 All-Copper Primary Heat Exchanger 3 Over Heat Film Wrap 4 Electronic Spark Ignition 5 199,900 Btu/h Modulating Burner 6 Electronic Control Board 7 Condensate Reservoir 8 Variable Speed Fan 9 Water Flow Control System 10 Modulating Gas Valve Condensate Neutralizer Discharge Outlet 3/4" Hot Water Outlet External Connection for Remote Control Cable 3/4" Cold 3/4" Gas Water Connection Inlet Venting Options and Installations PVC Vent System All indoor tankless units must be vented vertically or horizontally to the outdoors using manufacturer approved venting material. See the installation instructions for each specific model. (ULCS636 Pipe must be used for Canada.) Outdoor Venting details, including clearances and diagrams can be found in the "Use & Care Manual" of Rheem indoor tankless water heaters. Rheem.com 800.720.2076

  • 1
  • 2
  • 3
  • 4

Rheem.com
800.720.2076
Air Intake
(PVC Venting)
Exhaust
(PVC Venting)
1
2
3
5
4
6
7
8
9
10
Condensate
Neutralizer
Discharge
Outlet
3/4" Hot
Water
Outlet
External
Connection
for Remote
Control Cable
3/4" Cold
Water
Inlet
3/4" Gas
Connection
1
2
3
5
4
6
7
8
9
10
Condensate
Neutralizer
Discharge
Outlet
3/4" Hot
Water
Outlet
External
Connection
for Remote
Control Cable
3/4" Cold
Water
Inlet
3/4" Gas
Connection
Venting Options and
Installations
Superior Construction and Reliability
Indoor Direct Vent
Stainless Steel Secondary
Heat Exchanger
All-Copper Primary Heat
Exchanger
Over Heat Film Wrap
Electronic Spark Ignition
199,900 Btu/h
Modulating Burner
Electronic Control Board
Condensate Reservoir
Variable Speed Fan
Water Flow Control
System
Modulating Gas Valve
1
2
3
4
5
8
9
10
7
6
Outdoor
Stainless Steel Secondary
Heat Exchanger
All-Copper Primary Heat
Exchanger
Over Heat Film Wrap
Electronic Spark Ignition
199,900 Btu/h
Modulating Burner
Electronic Control Board
Condensate Reservoir
Variable Speed Fan
Water Flow Control
System
Modulating Gas Valve
1
2
3
4
5
8
9
10
7
6
PVC Vent System
Outdoor
All indoor tankless units must be vented
vertically or horizontally to the outdoors
using manufacturer approved venting
material. See the installation instructions
for each specific model. (ULCS636 Pipe
must be used for Canada.)
Venting details, including clearances and
diagrams can be found in the “Use & Care
Manual” of Rheem indoor tankless water
heaters.