Rheem H95 Direct Vent Indoor Series Brochure - Page 4
Rheem Prestige RTGH-95 Specifications for 3 Bathroom Homes, Rheem Prestige RTGH-84 Specifications - h95 tankless
View all Rheem H95 Direct Vent Indoor Series manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 4 highlights
Commercial Gas Water INTEGRATED HOME COMFORT Prestige Tankless Water Heaters Rheem Prestige RTGH-95 Specifications for 3 Bathroom Homes DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO. MODEL NUMBER RTGH-95DVLN GAS INPUT BTU/H TYPE TEMP. RANGE 11,000- Indoor 85° to 199,900 Direct Vent 140° F MIN. FLOW/ ACTIVATION GPM 0.26/0.40 GPM @ 77° RISE MAX. 4.9 GPM @ 45° RISE MAX. 8.4 MAX. GPM 9.5 CONNECTION WATER GAS HEIGHT WIDTH DEPTH 3/4 3/4 27-1/2 18-1/2 9-3/4 VENT DIAM. 2" or 3" PVC 2-Pipe SHIP. % OF D.O.E. ANN. WEIGHT ENERGY THERM. OP. COST (LBS.) FACTOR EFFICIENCY NAT/LP 82 .94 94% $194/326 RTGH-95XLN 11,000- Outdoor 85° to 0.26/0.40 4.9 199,900 140° F 8.4 9.5 3/4 3/4 27-1/2 18-1/2 9-3/4 N/A 82 .94 94% $194/326 Rheem Prestige RTGH-84 Specifications for 2-3 Bathroom Homes DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO. MODEL NUMBER RTGH-84DVLN GAS INPUT BTU/H TYPE TEMP. RANGE 11,000- Indoor 85° to 157,000 Direct Vent 140° F MIN. FLOW/ ACTIVATION GPM 0.26/0.40 GPM @ 77° RISE MAX. 3.9 GPM @ 45° RISE MAX. 6.6 MAX. GPM 8.4 CONNECTION WATER GAS HEIGHT WIDTH DEPTH 3/4 3/4 27-1/2 18-1/2 9-3/4 VENT DIAM. 2" or 3" PVC 2-Pipe SHIP. % OF D.O.E. ANN. WEIGHT ENERGY THERM. OP. COST (LBS.) FACTOR EFFICIENCY NAT/LP 82 .94 94% $194/326 RTGH-84XLN 11,000- Outdoor 85° to 0.26/0.40 3.9 157,000 140° F 6.6 8.4 3/4 3/4 27-1/2 18-1/2 9-3/4 N/A 82 .93 94% $198/333 Energy Factor and Average Annual Operating Costs based on D.O.E. (Department of Energy) test procedures. D.O.E. national average fuel rate natural gas $1.218/therm; LP $1.87/gallon. All models are available in Natural Gas and Propane (LP). For Propane replace the N with P when ordering. • SCAQMD 1146.2 compliant. • Factory set maximum temperature is 120° F. See Use and Care Manual for setting. • Consult factory for information on sizing the application. • Add a "C" to the model number when ordering Canadian models. Outdoor models are only for seasonal use in Canada. Please contact Rheem Canada Ltd for details. Vent Termination Kits are required for Direct Vent models. Contact your distributor for details. Proper gas pressure must be ensured to supply tankless gas water heaters - up to 199,900 Btu/h for RTGH-95 models, up to 157,000 Btu/h for RTGH-84 models. (Consult your gas supplier) Indoor Direct Vent 5 1/2" 6 1/4" 27 1/2" Model Number 35° 45° 50° RTGH-95 Water Flow (GPM) 9.5 8.4 7.6 RTGH-84 Water Flow (GPM) 8.4 6.6 6.0 Above estimates are for sizing purposes only. Temperature Rise (° F) 60° 70° 77° 80° 6.3 5.4 4.9 4.7 5.0 4.3 3.9 3.7 90° 100° 4.2 3.8 3.3 3.0 GPM Water Heater Flow Rate Curves 10 9 8 H95 Max Flow H84 Max Flow 7 6 5 4 3 2 1 0 10 20 35 45 50 60 70 77 80 90 100 120 140 Delta-T Maximum Vent Length (intake/outlet): Number of 90° Elbows 0 or 1 2 3 4 5 6 Maximum Length of 2" Straight Pipe 5.0 ft. (1.5 m) 3.5 ft. (1.0 m) 2.0 ft. (0.6 m) Not Available Not Available Not Available Maximum Length of 3" Straight Pipe 38.0 ft. (11.6 m) 36.5 ft. (11.1 m) 35.0 ft. (10.6 m) 33.5 ft. (10.2 m) 32.0 ft. (9.8 m) 30.5 ft. (9.3 m) (ULCS636 pipe must be used for Canada.) 18 1/2" 9 3/4" 4 1/4" 3 1/4" 2 3/4" 3 1/2" 6 3/4" 7 1/2" Outdoor 2 1/2" 2 3/4" 27 1/2" 9 3/4" 18 1/2" Formerly GAMA LEED Points = 2 4 1/4" 3 1/4" 2 3/4" 3 1/2" 6 3/4" 7 1/2" 2 1/2" 2 3/4" In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • 1.800.621.5622 Rheem Canada Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 • 1.800.268.6966 Rheem.com PRINTED IN U.S.A. 06/12 WP FORM NO. TK-901C Rev. 4