Ridgid WD1450 Owners Manual - Page 6

Replacement Filter Assembly

Page 6 highlights

SP6542-2.qxd 6/26/07 1:20 PM Page 6 Replacement Filter Assembly 1. Carefully slide the filter over the filter cage, sliding it over the center ring covering the 3 slots until the filter stops against the lid. 2. Place filter nut and filter plate onto threaded stud and tighten it down. Finger tighten only. NOTE: Lever of filter nut should be away from plate as shown. IMPORTANT: Do not overtighten as this may deform or crack the filter cage, or filter. NOTE: If filter cage or float needs to be removed or replaced, use a flat blade screwdriver and insert the blade near one of the tabs between the filter cage and the center ring of the lid. Pry the tab out of the slot. Tilt the cage and lift away from the lid. To replace, follow the assembly instructions below: Filter Nut Lever ! WARNING: For your own safety, never connect plug to power source outlet until all assembly steps are complete and you have read and understood the safety and operation instructions. Do not operate vac with any parts damaged or missing. Filter Cage Tabs (3) Float Solid End Filter Nut Filter Plate Filter Threaded Stud Filter Cage Slots (3) Power Head Assembly 3. Place the float over the opening in the center of the lid with the words "This Side Towards Lid" laying face down over the hole. ! WARNING: To reduce the risk of personal injury or damage to vac be sure to keep hands, fingers, or any other foreign objects out of the center opening when assembling the float. THIS SIDE TOWARD LID 4. Line up filter cage tabs with slots in the center ring of the lid. 5. Push on the filter cage until the tabs snap into slots for a secure fit. Filter Cage Tabs (3) Slots (3) Slots (3) 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

1. Carefully slide the filter over the filter
cage, sliding it over the center ring
covering the 3 slots until the filter stops
against the lid.
2. Place filter nut and filter plate onto
threaded stud and tighten it down.
Finger tighten only.
NOTE:
Lever of filter nut should be away
from plate as shown.
IMPORTANT:
Do not overtighten as this
may deform or crack the filter cage, or
filter.
NOTE:
If filter cage or float needs to be
removed or replaced, use a flat blade
screwdriver and insert the blade near one
of the tabs between the filter cage and
the center ring of the lid. Pry the tab out
of the slot. Tilt the cage and lift away from
the lid. To replace, follow the assembly
instructions below:
3. Place the float over the opening in the
center of the lid with the words "This
Side Towards Lid" laying face down
over the hole.
4. Line up filter cage tabs with slots in the
center ring of the lid.
5. Push on the filter cage until the tabs
snap into slots for a secure fit.
Replacement Filter Assembly
WARNING: For your own safety,
never connect plug to power source
outlet until all assembly steps are
complete and you have read and
understood the safety and operation
instructions. Do not operate vac
with any parts damaged or missing.
WARNING: To reduce the risk of
personal injury or damage to vac be
sure to keep hands, fingers, or any
other foreign objects out of the
center opening when assembling
the float.
Filter
Threaded Stud
Filter Cage
Slots (3)
Filter Nut
Filter Nut
Lever
Filter Plate
THIS SIDE
TOWARD LID
Filter Cage
Tabs (3)
Float
Solid End
Slots (3)
Filter Cage
Tabs (3)
Slots (3)
Power Head
Assembly
6
!
!
SP6542-2.qxd
6/26/07
1:20 PM
Page 6