Ryobi P739 Operation Manual - Page 12

Troubleshooting

Page 12 highlights

TTRROOUUBBLLEESSHHOOOOTTIINNGG PROBLEM Compressor will not run POSSIBLE CAUSE Battery is not charged Pressure switch bad Tank is full of air Internal overload switch is tripped SOLUTION Recharge battery pack Take compressor to service center Compressor will turn on when tank pressure drops to cut-in pressure Turn off compressor and allow unit to cool; remove and reinstall battery packs Motor hums but cannot run Shorted or open motor winding or runs slowly Defective check valve or unloader Take compressor to service center Take compressor to service center Internal overload switch trips Lack of proper ventilation/room temperature Move compressor to well-ventilated area repeatedly too high Electrical overload Turn off unit and allow to cool; remove and reinstall battery packs. Air tank pressure drops when Loose connections (fittings, tubing, etc.) compressor shuts off Loose drain valve / open drain valve Check valve leaking Check all connections with soap and water solution and tighten Tighten drain valve / close drain valve Take compressor to service center Excessive moisture in dis- Excessive water in air tank charge air High humidity Compressor runs continu- Defective pressure switch ously Excessive air usage Air output lower than normal Broken inlet valves Connections leaking DANGER: Do not disassemble check valve, tank drain valves or safety relief valve with air in tank - bleed tank. Drain tank Move to area of less humidity; use air line filter Take compressor to service center Decrease air usage; compressor not large enough for tool's requirement Take compressor to service center Tighten connections NOTE: ILLUSTRATIONS START ON PAGE 13 AFTER FRENCH AND SPANISH LANGUAGE SECTIONS. 12 - English

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

12 – English
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
SOLUTION
Compressor will not run
Battery is not charged
Pressure switch bad
Tank is full of air
Internal overload switch is tripped
Recharge battery pack
Take compressor to service center
Compressor will turn on when tank pressure
drops to cut-in pressure
Turn off compressor and allow unit to cool;
remove and reinstall battery packs
Motor hums but cannot run
or runs slowly
Shorted or open motor winding
Defective check valve or unloader
Take compressor to service center
Take compressor to service center
Internal overload switch trips
repeatedly
Lack of proper ventilation/room temperature
too high
Electrical overload
Move compressor to well-ventilated area
Turn off unit and allow to cool; remove and
reinstall battery packs.
Air tank pressure drops when
compressor shuts off
Loose connections (fittings, tubing, etc.)
Loose drain valve / open drain valve
Check valve leaking
Check all connections with soap and water
solution and tighten
Tighten drain valve / close drain valve
Take compressor to service center
DANGER:
Do not disassemble check valve, tank drain
valves or safety relief valve with air in tank
— bleed tank.
Excessive moisture in dis-
charge air
Excessive water in air tank
High humidity
Drain tank
Move to area of less humidity; use air line filter
Compressor runs continu-
ously
Defective pressure switch
Excessive air usage
Take compressor to service center
Decrease air usage; compressor not large
enough for tool’s requirement
Air output lower than normal
Broken inlet valves
Connections leaking
Take compressor to service center
Tighten connections
NOTE: ILLUSTRATIONS START ON PAGE 13 AFTER FRENCH
AND SPANISH LANGUAGE SECTIONS.
TROUBLESHOOTING