Samsung DV422GWHDWR/AA User Manual Ver.1.0 (English) - Page 9

Gas Model, Warning

Page 9 highlights

TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. GAS MODEL Radiant Sensor(10RS) Resistance value < 1 ٠If resistance is infinite, replace Radiant sensor Gas Valve(25M01A) Valve 1-2 : Resistance value 1.2K ٠Valve 1-3 : Resistance value 0.5K ٠Valve 4-5 : Resistance value 1.2K ٠If resistance is infinity, replace Valve Igniter(101D) Resistance value 40~400 ٠If resistance is infinite, replace Igniter Thermostat (60T21 Hi-Limit)230F-50F Resistance value < 1 ٠If resistance is infinity, replace Thermostat 9 [HUDSON]_Technical_information-03171A_EN.indd 9 2012-02-03 �� 5:01:23

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

9
GAS MODEL
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Radiant Sensor(10RS)
Resistance value < 1 Ω
If resistance is infinite, replace Radiant sensor
Igniter(101D)
Resistance value 40~400 Ω
If resistance is infinite, replace Igniter
Gas Valve(25M01A)
Valve 1-2 : Resistance value 1.2K Ω
Valve 1-3 : Resistance value 0.5K Ω
Valve 4-5 : Resistance value 1.2K Ω
If resistance is infinity, replace Valve
Thermostat (60T21 Hi-Limit)230F-50F
Resistance value < 1 Ω
If resistance is infinity, replace Thermostat
[HUDSON]_Technical_information-03171A_EN.indd
9
2012-02-03
�� 5:01:23