Samsung DV457EVGSWR/AA Trouble Shooting Guide User Manual Ver.1.0 (English, Fr - Page 11

Thermistor, Gas Model, Warning

Page 11 highlights

TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. THERMISTOR 238.23Ω @ 25 °C 77 GAS MODEL Radiant Sensor(10RS) Resistance value < 1 Ω If resistance is infinite, replace Radiant sensor Gas Valve(25M01A) Valve 1-2 : Resistance value about 1365 Ω Valve 1-3 : Resistance value about 560 Ω Valve 4-5 : Resistance value about 1325 Ω If resistance is infinity, replace Valve Igniter(101D) Resistance value 40~400 Ω If resistance is infinite, replace Igniter Thermostat (60T21 Hi-Limit)230F-50F Resistance value < 1 Ω If resistance is infinity, replace Thermostat 11 Technical_information-02835D-01_EN.indd 11 2012-03-26 2:28:51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

11
THERMISTOR
GAS MODEL
TROUBLE SHOOTING
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before
servicing, unless testing requires power.
Radiant Sensor(10RS)
Resistance value < 1 Ω
If resistance is infinite, replace Radiant sensor
Igniter(101D)
Resistance value 40~400 Ω
If resistance is infinite, replace Igniter
Gas Valve(25M01A)
Valve 1-2 : Resistance value about 1365 Ω
Valve 1-3 : Resistance value about 560 Ω
Valve 4-5 : Resistance value about 1325 Ω
If resistance is infinity, replace Valve
Thermostat (60T21 Hi-Limit)230F-50F
Resistance value < 1 Ω
If resistance is infinity, replace Thermostat
238.23ω @ 25 °C 77
Technical_information-02835D-01_EN.indd 11
Technical_information-02835D-01_EN.indd
11
2012-03-26
2:28:51
2012-03-26
2:28:51