Samsung DV457EVGSWR/AA Trouble Shooting Guide User Manual Ver.1.0 (English, Fr - Page 12
WARNING, Sensor Bars & temperature sensor check
View all Samsung DV457EVGSWR/AA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 12 highlights
TROUBLE SHOOTING WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power. CN1 - AC Power Port - Door Detection Sensor - Motor Switch Check CN4 LCD connector (BEST only) RY5 - Motor Relay Switch RY7 - Heater1 Relay Switch RY6 - Heater2 Relay Switch - ELEC model only Sensor Bars & temperature sensor check Sensor Bars - Disconnect harness and test Pink wire Pin 4 to Orange wire Pin 5. Approx ∞ Ω without laundry Approx 190Ω ± 10% with wet clothes Cycling Thermistor1 - Disconnect harness and test Blue wire Pin 3 to Red wire Pin 6. Approx 10 KΩ at 25 °C / 77 °F Cycling Thermistor2 - Disconnect harness and test Yellow wire Pin 2 to White wire Pin 7. Approx 238.231 KΩ at 25 °C / 77 °F 12 Technical_information-02835D-01_EN.indd 12 2012-03-26 2:28:52