Samsung DV50K8600GV/A3 User Manual - Page 19

STEP 3, Connect the electrical wiring

Page 19 highlights

Installation STEP 3 Connect the electrical wiring First, read through the "Electrical requirements" section, and then follow these steps. 3-wire system 1. Loosen or remove the center terminal D block. 2. Connect the neutral wire (white or C center wire) of the power cable to the A center, silver-colored terminal screw of the terminal block. Tighten the screws. 3. Connect the other wires to outer terminal block screws. Tighten the B screws. 4. Tighten the strain relief screws. E 5. Insert the terminal block cover into the rear panel of the dryer. Then, secure the cover with a hold-down screw. CAUTION A. External ground connector B. Neutral grounding wire (white) C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. ¾" (1.9 cm) UL-listed strain relief • To convert from the 4-wire system to 3-wire system, connect the ground strap to the terminal block support to ground the dryer frame to the neutral conductor. • Ring-type terminals are recommended. If using strap terminals, make sure they are tightened. DV8700K-03170T-01_EN (US).indd 19 English 19 2015-12-08 1:05:03

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

Installation
English
19
STEP 3
Connect the electrical wiring
First, read through the “
Electrical requirements
” section, and then follow these steps.
3-wire system
A
B
E
C
D
A.
External ground connector
B.
Neutral grounding wire (white)
C.
Center silver-colored terminal block
screw
D.
Neutral wire (white or center wire)
E.
¾” (1.9 cm) UL-listed strain relief
1.
Loosen or remove the center terminal
block.
2.
Connect the neutral wire (white or
center wire) of the power cable to the
center, silver-colored terminal screw of
the terminal block. Tighten the screws.
3.
Connect the other wires to outer
terminal block screws. Tighten the
screws.
4.
Tighten the strain relief screws.
5.
Insert the terminal block cover into the
rear panel of the dryer. Then, secure the
cover with a hold-down screw.
CAUTION
To convert from the 4-wire system
to 3-wire system, connect the ground
strap to the terminal block support to
ground the dryer frame to the neutral
conductor.
Ring-type terminals are recommended.
If using strap terminals, make sure they
are tightened.