STEP 3, Connect the electrical wiring
![]() |
View all Samsung DVE52M8650V/A3 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 19 highlights
Installation STEP 3 Connect the electrical wiring First, read through the "Electrical requirements" section, and then follow these steps. 3-wire system C A B D E A. External ground connector B. Neutral grounding wire (white) C. Center silver-colored terminal block screw D. Neutral wire (white or center wire) E. ¾" (1.9 cm) UL-listed strain relief 1. Loosen or remove the center terminal block. 2. Connect the neutral wire (white or center wire) of the power cable to the center, silver-colored terminal screw of the terminal block. Tighten the screws. 3. Connect the other wires to outer terminal block screws. Tighten the screws. 4. Tighten the strain relief screws. 5. Insert the terminal block cover into the rear panel of the dryer. Then, secure the cover with a hold-down screw. CAUTION • To convert from the 4-wire system to 3-wire system, connect the ground strap to the terminal block support to ground the dryer frame to the neutral conductor. • Ring-type terminals are recommended. If using strap terminals, make sure they are tightened. DV8650M-03170X-00_EN.indd 19 English 19 2017-01-06 4:36:56