Samsung NE59M4310SS/AA Installation Guide - Page 10
Step 5. Replacing The Access Cover
View all Samsung NE59M4310SS/AA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
Installing a 4-wire conduit • Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make the connection. Connect wires according to this Step 4 depending on the number of wires. • Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. 1. Loosen the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. 2. Cut and discard the ground strap. Do not discard any screws. 3. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw (removed earlier). 4. Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening. 5. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. 6. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws since it could damage the wires. 7. Go to step 5 and proceed with the installation. Black White Red Neutral terminal Ground strap Live 1 Live 2 Ground plate Wire tips White Black Red Ground wire (Green) CAUTION CAUTION You must check voltage after connecting power cord. Live 1 - Neutral Live 2 - Neutral Live 1 - Live 2 120 V 120 V 208 V / 240 V STEP 5. REPLACING THE ACCESS COVER Replace the access cover on the range back. To replace the wire cover, insert double projections in the pockets located below the opening and tighten the screw. Install_30_Electric_Range_USA_DG68-00108G-09_EN+MES.indb 10 English - 10 2018-07-31 3:48:05