Step 5. Replacing The Access Cover

Page 10 highlights

Installing a 4-wire conduit • Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make the connection. Connect wires according to this Step 4 depending on the number of wires. • Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes. 1. Loosen the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them. 2. Cut and discard the ground strap. Do not discard any screws. 3. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw (removed earlier). 4. Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening. 5. Insert the two side bare wire tips into the lower left and the lower right terminal block openings. 6. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws since it could damage the wires. 7. Go to step 5 and proceed with the installation. Black White Red Neutral terminal Ground strap Live 1 Live 2 Ground plate Wire tips White Black Red Ground wire (Green) CAUTION CAUTION You must check voltage after connecting power cord. Live 1 - Neutral Live 2 - Neutral Live 1 - Live 2 120 V 120 V 208 V / 240 V STEP 5. REPLACING THE ACCESS COVER Replace the access cover on the range back. To replace the wire cover, insert double projections in the pockets located below the opening and tighten the screw. Install_30_Electric_Range_USA_DG68-00108G-09_EN+MES.indb 10 English - 10 2018-07-31 3:48:05

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

Installing a 4-wire conduit
Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make
the connection. Connect wires according to this Step 4 depending on the number of wires.
Wire used, location and enclosure of splices, etc., must conform to good wiring practices and local codes.
1.
Loosen the 3 lower terminal screws from the terminal block. Remove the ground screw and
ground plate and retain them.
2. Cut and discard the ground strap. Do not discard any screws.
3.
Insert the ground bare wire tip between the range frame and the ground plate (removed earlier)
and secure it in place with the ground screw (removed earlier).
4.
Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening.
5.
Insert the two side bare wire tips into the lower left and the lower right terminal block openings.
6.
Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the
screws since it could damage the wires.
7.
Go to
step 5
and proceed with the installation.
Ground strap
Ground plate
White
Black
Red
Neutral
terminal
Ground
wire
(Green)
Wire tips
White
Black
Red
Live 2
Live 1
CAUTION
CAUTION
You must check voltage after connecting power cord.
Live 1 - Neutral
120 V
Live 2 - Neutral
120 V
Live 1 - Live 2
208 V / 240 V
STEP 5. REPLACING THE ACCESS COVER