Samsung NX58K9850SG/AA Installation Guide - Page 17
Gas requirements, Fig. 1, IMPORTANT
View all Samsung NX58K9850SG/AA manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 17 highlights
CAUTION Do NOT lift or handle the unit by the cooktop frame. C2 C1 C4 C3 Fig. 1 1. The counter top around the cut-out should be flat and leveled (See hatched area on Fig. 1). 2. Before installing the unit, measure the heights of the two cabinet sides (C1~C4), front and back (See Fig. 1) from the floor to the top of the counter. 3. Level the range using the four leveling legs so that the height from the floor to the underside of the cooktop frame is greater than the tallest cabinet measurement by at least 1/16". 4. Slide the unit into the cabinet (DO NOT PUSH THE UNIT HARD). Make sure the center of the unit aligns with the center of the cabinet cut-out. 5. The metal flange under each side of the cooktop MUST be placed over the cabinet countertop for proper unit support. The cooktop should NOT rest directly on the countertop or else it could cause damage to the cooktop voiding the warranty. Level the unit if needed. IMPORTANT: MAKE SURE the unit is supported by the leveling legs and NOT by the cooktop itself. Gas requirements Provide adequate gas supply This range is designed to operate at a pressure of 5 in (13 cm) of water column on natural gas or 10 in (25 cm) of water column on LP gas (propane or butane). Make sure you are supplying your range with the type of gas for which it is designed. Do not attempt to convert the appliance from the gas specified in this manual to a different gas without consulting the gas supplier. This range is convertible for use on natural or propane gas. If you decide to use this range on LP gas, conversion must be made by a qualified LP installer before attempting to operate the range. For proper operation, the pressure of natural gas supplied to the regulator must be between 5 in and 13 in (13 cm and 33 cm) of water column. For LP gas, the pressure supplied must be between 10 in and 13 in (25 cm and 33 cm) of water column. When checking for proper operation of the regulator, the inlet pressure must be at least 1 in (2.5 cm) greater than the operating (manifold) pressure as given. The pressure regulator located at the inlet of the range manifold must remain in the supply line regardless of whether natural or LP gas is being used. A flexible-metal appliance connector used to connect the range to the gas supply line should have an I.D. of 0.5 in (1.3 cm) and be 5 ft (152 cm) in length for ease of installation. In Canada, flexible connectors must be single-wall metal connectors no longer than 6 ft (183 cm) in length. Do not kink or damage the flexible metal tubing when moving the range. Installation requirements English 17