Samsung SCP-3120 User Manual - Page 49

Main Menu/Camera Setting/Exposure

Page 49 highlights

FUNCTIONAL DESCRIPTION Exposure ► Main Menu/Camera Setting/Exposure The Exposure settings are to control the camera's exposure meter. • Brightness : Adjusts the screen brightness. (Over 32: Brighter, Under 32: Darker) It may not fully operable under extremely low lighting condition. • Iris : - AUTO : Automatically adjusts the exposure meter. - MANUAL : Enables manual adjustment of the exposure meter. (Over 32: Brighter, Under 32: Darker) • Shutter : Controls the camera's electronic shutter. - OFF : The shutter speed is fixed at 1/60 for NTSC and 1/50 for PAL. Operates when Iris is on the Auto Mode. - A.FLK : Select this setting when you experience picture flickering. Flickering can happen when artificial lighting frequencies clash with camera frame rates. - MANUAL : Enables manual adjustment of the shutter speed. • Sens-Up : - AUTO : Automatically detects light levels and maintains a clear picture at night or under low-light conditions. - SENS-UP LIMIT : Adjusts to the maximumpowered zoom per frame. Main Menu Camera Setting Sequence Setting P/T Setting OSD Setting Alarm Setting Initialize Password Setting Status Camera Setting Zoom/Focus White Balance Exposure Back Light AGC DNR XDR Day/Night Others Exposure Brightness Iris Shutter Sens-Up ATW(IN) OFF --MEDIUM OFF 32 AUTO OFF AUTO M  While the Internal Sync mode is in effect, setting the shutter to '---' and facing the camera directly to a bright light source may cause poor camera performance.  Brightness is disabled when the Iris is in Manual mode.  Shutter is disabled when the WDR is turned on.  Sens-Up is disabled when the shutter is in Manual mode. English English _ 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

English
English
_ 49
FUNCTIONAL DESCRIPTION
Exposure
Main Menu/Camera Setting/Exposure
The Exposure settings are to control the camera’s
exposure meter.
Brightness :
Adjusts the screen brightness.
(Over 32: Brighter, Under 32: Darker)
It may not fully operable under extremely low lighting
condition.
Iris :
AUTO :
Automatically adjusts the exposure meter.
MANUAL :
Enables manual adjustment of the
exposure meter.
(Over 32: Brighter,
Under 32: Darker)
Shutter :
Controls the camera’s electronic shutter.
OFF :
The shutter speed is fixed at 1/60 for
NTSC and 1/50 for PAL. Operates when
Iris is on the Auto Mode.
A.FLK :
Select this setting when you experience
picture flickering. Flickering can happen
when artificial lighting frequencies clash
with camera frame rates.
MANUAL :
Enables manual adjustment of the
shutter speed.
Sens-Up :
AUTO :
Automatically detects light levels and
maintains a clear picture at night or
under low-light conditions.
SENS-UP LIMIT :
Adjusts to the maximum-
powered zoom per frame.
While the Internal Sync mode is in effect, setting the shutter to '---' and facing the
camera directly to a bright light source may cause poor camera performance.
Brightness is disabled when the Iris is in Manual mode.
Shutter is disabled when the WDR is turned on.
Sens-Up is disabled when the shutter is in Manual mode.
-
-
-
-
-
-
-
M
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Password Setting
Status
Camera Setting
Zoom/Focus
White Balance
ATW(IN)
Exposure
Back Light
OFF
AGC
---
DNR
MEDIUM
XDR
OFF
Day/Night
Others
Exposure
Brightness
32
Iris
AUTO
Shutter
OFF
Sens-Up