Connection RS-485 communication control Connecting to RS-485 Control Cable CONTROL CABLE WHITE (TRX+) BLCAK (TRX-) SPEC RS-485+ RS-485- WHITE (TRX+) BLACK (TRX-) Using RS-485 communication will enable you to control the OSD menu from a SAMSUNG TECHWIN System Controller or DVR. (1) Connection to a PC. Connect the camera to the PC via a RS-485 converter using RS-485 and a serial cable. EX) SERIAL PORT OF THE PC(COM1) → SERIAL CABLE → RS-485 CONVERTER → RS-485 CONTROL CABLE (2) Connection to a DVR or System Controller. C onnect the RS-485 cable to the connection ports of the DVR or System Controller. 485 Control Board Connection Port (+) CONNECTION TERMINAL (-) CONNECTION TERMINAL RS-485 Control Port WHITE (TRX+) BLACK (TRX-) * RS-485 Communication establishment initial value Item Camera ID BAUD RATE Initial value 1 9600 UART MODE 8-NONE-1 RET PKT ENABLE Notes • When making a control system to control the camera, please use to the SAMSUNG-T PROTOCOL or PELCO-P, PELCO-D, VICON, PANASONIC, BOSCH, HONEYWELL, SAMSUNG-E PROTOCOL. • When you connecting to RS-485 control cable, please peel off the outer skin inside the RS-485 control cable. • In case of SCC-101 connection, change communication mode to『8-E-1』at 『Communication configuration』menu. (For more information, refer to SCC-101 manual.) COLOR DOME CAMERA 14 User Guide Using Coaxial Communications • C oaxial Communications System • O SD Control method CAMERA SET UP DOWN LEFT RIGHT DVR MENU / ENTER UP KEY DOWN KEY LEFT KEY RIGHT KEY CONTROLLER OSD KEY JOYSTICK UP JOYSTICK DOWN JOYSTICK LEFT JOYSTICK RIGHT DVR DVD • : BNC • ---- : RS-485 - Video Cable The camera's video output port is connected to the monitor with a BNC coaxial cable, shown below : If the distance between the camera and the monitor exceeds the recommended maximum, please use an auxiliary video amp. Distance 300m 450m 600m Recommended Cable Specification 3C2V(RG-59/U) 5C2V(RG-6/U) 7C2V(RG-11/U) Notes • If the camera is controlled through coaxial communication, please use a video amp intended for coaxial communications. Regular video amps do not transfer coaxial signals. COLOR DOME CAMERA 15 User Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19

COLOR DOME CAMERA
User Guide
14
COLOR DOME CAMERA
User Guide
15
RS-485 communication control
Using RS-485 communication will enable you to control the OSD menu from a SAMSUNG
TECHWIN System Controller or DVR.
(1) Connection to a PC.
Connect the camera to the PC via a RS-485 converter using RS-485 and a serial cable.
EX) SERIAL PORT OF THE PC(COM1)
SERIAL CABLE
RS-485 CONVERTER
RS-485
CONTROL CABLE
Connecting to RS-485 Control Cable
CONTROL CABLE
SPEC
WHITE (TRX+)
RS-485+
BLCAK (TRX-)
RS-485-
Connection
• When making a control system to control the camera, please use to the SAMSUNG-T
PROTOCOL or PELCO-P, PELCO-D, VICON, PANASONIC, BOSCH, HONEYWELL, SAMSUNG-E
PROTOCOL.
• When you connecting to RS-485 control cable, please peel off the outer skin inside the
RS-485 control cable.
• In case of SCC-101 connection, change communication mode to
8-E-1
at
Communication configuration
menu. (For more information, refer to SCC-101 manual.)
Notes
* RS-485 Communication establishment initial value
485 Control Board Connection Port
RS-485 Control Port
(+) CONNECTION TERMINAL
WHITE (TRX+)
(-) CONNECTION TERMINAL
BLACK (TRX-)
Item
Camera ID
BAUD RATE
UART MODE
RET PKT
Initial value
1
9600
8-NONE-1
ENABLE
(2) Connection to a DVR or System Controller.
Connect the RS-485 cable to the connection ports of the DVR or System Controller.
• Coaxial Communications System
• OSD Control method
DVR
Using Coaxial Communications
CAMERA
DVR
CONTROLLER
SET
MENU / ENTER
OSD KEY
UP
UP KEY
JOYSTICK UP
DOWN
DOWN KEY
JOYSTICK DOWN
LEFT
LEFT KEY
JOYSTICK LEFT
RIGHT
RIGHT KEY
JOYSTICK RIGHT
Distance
Recommended Cable Specification
300m
3C2V(RG-59/U)
450m
5C2V(RG-6/U)
600m
7C2V(RG-11/U)
– Video Cable
The camera's video output port is connected to the monitor with a BNC coaxial cable,
shown below : If the distance between the camera and the monitor exceeds the
recommended maximum, please use an auxiliary video amp.
• If the camera is controlled through coaxial communication, please use a video amp intended
for coaxial communications. Regular video amps do not transfer coaxial signals.
Notes
WHITE (TRX+)
BLACK (TRX
-
)
DVD
: BNC
• ---- : RS-485