Sanyo PLC-WU3800 RS232 Expand - Page 34
Lamp Command, CF_LAMPH Command, CF_LAMPMODE Command
View all Sanyo PLC-WU3800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
PLC-WU3800 Expand Serial Command Functional Specifications 8.8 Lamp Command 8.8.1 CF_LAMPH Command Command "CF_LAMPH_%1"[CR] %1 "RST" Details Reset total lamp running time This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.8.2 CF_LAMPMODE Command Command "CF_LAMPMODE_%1"[CR] "HIGH Set lamp to High mode status "NORMAL" ------- Set lamp to Normal mode status "ECO Set lamp to 3L mode status %1 "AUTO Set lamp to Auto mode status "UP Switch Lamp mode forward (Auto → High → Normal → Eco...) "DN Switch Lamp mode backward (Eco → Normal → High → Auto...) Details Select Lamp Mode The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF. This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 34/74