Sanyo PLC-WU3800 RS232 Expand - Page 45
CF_FILTIMER Command, 10.30 CF_FILH Command, 10.31 CF_FDEFAULT Command
View all Sanyo PLC-WU3800 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
PLC-WU3800 Expand Serial Command Functional Specifications 8.10.29 CF_FILTIMER Command Command "CF_FILTIMER_%1"[CR] "100 Set 100 hours "200 Set 200 hours "300 Set 300 hours "OFF No warning display %1 "UP Switch Filter timer forward Off →100 → 200 → 300 → Off "DN Switch Filter timer backward Off → 300 → 200 → 100 Details Set timer of Filter warning display. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.30 CF_FILH Command Command "CF_FILH_%1"[CR] %1 "RST Reset Filter used time Details Reset filter used time Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 8.10.31 CF_FDEFAULT Command Command "CF_FDEFAULT_%1"[CR] %1 "RST" Details Set the value to Factory Default This command is available in normal Power ON status. Acceptable "000"[CR] Response Unacceptable "Error Code"[CR] 45/74