Condition/Problem, Things to Check, Solution
View all Schwinn Journey 1.0 Upright Bike manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Condition/Problem Unit rocks/does not sit level Pedals loose/unit difficult to pedal Clicking sound when pedaling Seat post movement Things to Check Check data cable connections/orientation Reset Machine Check magnet position (requires shroud removal) Check Speed Sensor (requires shroud removal) Check leveler adjustment Solution Be sure cable is connected securely and oriented properly. Small latch on connector should line up and snap into place. Unplug unit from electrical outlet for 3 minutes. Reconnect to outlet. Magnet should be in place on pulley. Speed sensor should be aligned with magnet and connected to data cable. Realign sensor if necessary. Replace if there is any damage to the sensor or the connecting wire. Adjust levelers until bike is level. Check surface under unit Check pedal to crank arm connection Check pedal to crank arm connection Check locking pin Check adjustment knob Adjustment may not be able to compensate for extremely uneven surfaces. Move bike to level area. Pedal should be tightened securely to crank. Insure connection is not cross-threaded. Remove pedals and reattach. Be sure adjustment pin is locked into one of the seat post adjustment holes. Be sure knob is securely tightened. 34