Seagate ST32000641AS Barracuda XT Series SATA Product Manual - Page 16
Environmental specifications
UPC - 900000004940
View all Seagate ST32000641AS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
2.7 Environmental specifications 2.7.1 Ambient temperature Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 69°C (156°F) within the operating ambient conditions. Operating: 0° to 60°C (32° to 140°F) Nonoperating: * -40° to 70°C (-40° to 158°F) * See Section for reliability projections. 2.7.2 Temperature gradient Operating: Nonoperating: 20°C per hour (68°F per hour max), without condensation 30°C per hour (86°F per hour max) 2.7.3 Humidity 2.7.3.1 Relative humidity Operating: Nonoperating: 5% to 95% noncondensing (30% per hour max) 5% to 95% noncondensing (30% per hour max) 2.7.3.2 Wet bulb temperature Operating: Nonoperating: 37.7°C (99.9°F max) 40°C (104°F max) 2.7.4 Altitude Operating: Nonoperating: -60.96m to 3,048m (-200 ft to 10,000+ ft) -60.96m to 12,192m (-200 ft to 40,000+ ft) 10 Barracuda XT Series SATA Product Manual, Rev. C