Seagate ST3300457FC Cheetah 15K.6 SAS Product Manual - Page 36
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour,
View all Seagate ST3300457FC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
ST3300656SS model Typical power dissipation under idle conditions in 3Gb operation is 10.26 watts (35.01 BTUs per hour). To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure 4). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5 volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123. Figure 6. ST3300656SS, 3 Gbit, DC current and power vs. input/output operations per second 32 Cheetah 15K.6 SAS Product Manual, Rev. B
32
Cheetah 15K.6 SAS Product Manual, Rev. B
ST3300656SS
model
Typical power dissipation under idle conditions in 3Gb operation is 10.26 watts (35.01 BTUs per hour).
To obtain operating power for typical random read operations, refer to the following I/O rate curve (see Figure
4). Locate the typical I/O rate for a drive in your system on the horizontal axis and read the corresponding +5
volt current, +12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by
3.4123.
Figure 6.
ST3300656SS, 3 Gbit, DC current and power vs. input/output operations per second