Seagate ST3300457FC Cheetah 15K.6 SAS Product Manual - Page 74

additional sinusoidal jitter

Page 74 highlights

The leading and trailing edge slopes of figure 18 shall be preserved. As a result the amplitude value of Z1 is less than that given in table 30 and Z1TOL and Z1OP shall be defined from those slopes by the following equa- tion: Z1TOL = Z1OP x -X----2---O----P 0---,----5---)---x---a---d---d----i-t--i-o---n----a---l---s---i-n----u---s---o---i--d---a---l---j--i-t--t-e----r--)---------X-----1---O----PX2OP - X1OP where: Z1TOL is the value for Z1 to be used for the tolerance masks; and Z1OP, X1OP, and X2OP are the values in table 30 for Z1, X1, and X2. The X1 points in the receive tolerance masks are greater than the X1 points in the receive masks, due to the addition of sinusoidal jitter. Figure 20 defines the sinusoidal jitter mask. Peak-topeak sinusoidal jitter (in UI) 1.5 Sinusoidal jitter frequency (log/log plot) FNOM = 1.5 x 10 9 for 1.5 Gbps FNOM = 3.0 x 10 9 for 3.0 Gbps 1.0 0.1 0 FNOM / 25,000 FNOM / 1,667 Frequency (in kHz) Figure 20. Sinusoidal jitter mask 70 Cheetah 15K.6 SAS Product Manual, Rev. B

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90

70
Cheetah 15K.6 SAS Product Manual, Rev. B
The leading and trailing edge slopes of figure 18 shall be preserved. As a result the amplitude value of Z1 is
less than that given in table 30 and Z1
TOL
and Z1
OP
shall be defined from those slopes by the following equa-
tion:
where:
Z1
TOL
is the value for Z1 to be used for the tolerance masks; and
Z1
OP
, X1
OP
, and X2
OP
are the values in table 30 for Z1, X1, and X2.
The X1 points in the receive tolerance masks are greater than the X1 points in the receive masks, due to the
addition of sinusoidal jitter.
Figure 20 defines the sinusoidal jitter mask.
Figure 20.
Sinusoidal jitter mask
Z
1
TOL
Z
1
OP
x
X
2
OP
05
,
(
)
x
additional sinusoidal jitter
(
)
X
1
OP
X
2
OP
X
1
OP
----------------------------------------------------------------------------------------------------------------------------------
=
F
NOM
/ 25,000
F
NOM
/ 1,667
Sinusoidal jitter frequency
(log/log plot)
Peak-to-
peak
sinusoidal
jitter
(in UI)
F
NOM
= 1.5 x 10
9
for 1.5 Gbps
F
NOM
= 3.0 x 10
9
for 3.0 Gbps
1.5
0
0.1
Frequency (in kHz)
1.0