Seagate ST373207FC Cheetah 10K.7 FC Product Manual - Page 64

Cheetah 10K.7 FC Product Manual, Rev. D, Table 19 identifies the N_Port Login access payload values

Page 64 highlights

9.1.5 Fibre Channel port login accept Table 19 identifies the N_Port Login access payload values. Table 19: N_Port Login Accept (ACC) payload Bytes 0-15 02 00 00 00 20 20 00 00 88 00 FS FS 00 FF 00 01 Common 16-31 00 00 01 F4 20 PP CC CC CC UI UI UI 20 00 CC CC 32-35 CC UI UI UI 36-47 00 00 00 00 00 00 00 00 00 00 00 00 Class 1 48-51 00 00 00 00 52-63 00 00 00 00 00 00 00 00 00 00 00 00 Class 2 64-67 00 00 00 00 68-79 80 00 00 00 00 00 FS FS 00 FF 00 00 Class 3 80-83 00 01 00 00 84-95 00 00 00 00 00 00 00 00 00 00 00 00 Reserved 96-99 00 00 00 00 100-111 00 00 00 00 00 00 00 00 00 00 00 00 Vendor - 112-115 00 00 00 00 Version CC Bytes (22, 23 and 24) and (30, 31 and 32) are currently factory set to 00 04 CF respectively (subject to change). FS Receive buffer field size. The drive returns and uses the receive buffer size from the N_Port Login Class 3 receive buffer. UI Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and Node Name fields. PP Port identifier field. 01 P_LOGI received on Port A. 02 P_LOGI received on Port B. 9.1.6 Fibre Channel Process Login Table 20 lists the process login payload data. Table 20: Process Login (PLRI) payload Bytes 0-15 20 10 00 14 08 00 20 00 XX XX XX XX XX XX XX XX 16-19 00 00 00 22 XX Indicates fields that are not used. 52 Cheetah 10K.7 FC Product Manual, Rev. D

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

52
Cheetah 10K.7 FC Product Manual, Rev. D
9.1.5
Fibre Channel port login accept
Table 19 identifies the N_Port Login access payload values.
Table 19:
N_Port Login Accept (ACC) payload
9.1.6
Fibre Channel Process Login
Table 20 lists the process login payload data.
Table 20:
Process Login (PLRI) payload
XX
Indicates fields that are not used.
Bytes
0-15
02
00
00
00
20
20
00
00
88
00
FS
FS
00
FF
00
01
Common
16-31
00
00
01
F4
20
PP
CC
CC
CC
UI
UI
UI
20
00
CC
CC
32-35
CC
UI
UI
UI
36-47
00
00
00
00
00
00
00
00
00
00
00
00
Class 1
48-51
00
00
00
00
52-63
00
00
00
00
00
00
00
00
00
00
00
00
Class 2
64-67
00
00
00
00
68-79
80
00
00
00
00
00
FS
FS
00
FF
00
00
Class 3
80-83
00
01
00
00
84-95
00
00
00
00
00
00
00
00
00
00
00
00
Reserved
96-99
00
00
00
00
100-111
00
00
00
00
00
00
00
00
00
00
00
00
Vendor -
112-115
00
00
00
00
Version
CC
Bytes (22, 23 and 24) and (30, 31 and 32) are currently factory set to 00 04 CF respectively (subject to change).
FS
Receive buffer field size. The drive returns and uses the receive buffer size from the N_Port Login Class 3 receive
buffer.
UI
Unique identifier. This 24-bit field is uniquely assigned to the drive. This same UI appears in the Port Name and
Node Name fields.
PP
Port identifier field.
01
P_LOGI received on Port A.
02
P_LOGI received on Port B.
Bytes
0-15
20
10
00
14
08
00
20
00
XX
XX
XX
XX
XX
XX
XX
XX
16-19
00
00
00
22