Seagate ST38421A Product Manual - Page 19

Environmental tolerances, Ambient temperature, Temperature gradient, Humidity, 8.3.1, Relative - hard drive

Page 19 highlights

U4 Family Product Manual, Rev. D 11 drive buffer is enabled, the heads are parked and the spindle is at rest. The drive accepts all commands and returns to Active mode any time disc access is necessary. • Sleep mode The drive enters Sleep mode after receiving a Sleep command from the host. In Sleep mode, the drive buffer is disabled, the heads are parked and the spindle is at rest. The drive leaves Sleep mode after it receives a Hard Reset or Soft Reset from the host. After receiving a reset, the drive exits Sleep mode and enters Active mode with all current translation parameters intact. • Idle and Standby timers Each time the drive performs an Active function (read, write or seek), the standby timer is reinitialized and begins counting down from its specified delay times to zero. If the standby timer reaches zero before any drive activity is required, the drive makes a transition to Standby mode. In both Idle and Standby mode, the drive accepts all commands and returns to Active mode when disc access is necessary. 1.8 Environmental tolerances 1.8.1 Ambient temperature Operating Nonoperating 0° to 55°C (32° to 131°F) -40° to 70°C (-40° to 158°F) Note. Above 1,000 feet (305 meters), the maximum temperature is derated linearly to 112°F (44°C) at 10,000 feet (3,048 meters). Operating ambient temperature is defined as the temperature of the environment immediately surrounding the drive. 1.8.2 Temperature gradient Operating/Nonoperating 20°C/hr (36°F/hour) max, without condensation 1.8.3 Humidity 1.8.3.1 Relative Humidity Operating 5% to 90% noncondensing (30% per hour max) Nonoperating 5% to 95% noncondensing (30% per hour max)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42

U4 Family Product Manual, Rev. D
11
drive buffer is enabled, the heads are parked and the spindle is at rest.
The drive accepts all commands and returns to Active mode any time
disc access is necessary.
Sleep mode
The drive enters Sleep mode after receiving a Sleep command from
the host. In Sleep mode, the drive buffer is disabled, the heads are
parked and the spindle is at rest. The drive leaves Sleep mode after
it receives a Hard Reset or Soft Reset from the host. After receiving a
reset, the drive exits Sleep mode and enters Active mode with all
current translation parameters intact.
Idle and Standby timers
Each time the drive performs an Active function (read, write or seek),
the standby timer is reinitialized and begins counting down from its
specified delay times to zero. If the standby timer reaches zero before
any drive activity is required, the drive makes a transition to Standby
mode. In both Idle and Standby mode, the drive accepts all commands
and returns to Active mode when disc access is necessary.
1.8
Environmental tolerances
1.8.1
Ambient temperature
Note.
Above 1,000 feet (305 meters), the maximum temperature is
derated linearly to 112°F (44°C) at 10,000 feet (3,048 meters).
Operating ambient temperature is defined as the temperature of
the environment immediately surrounding the drive.
1.8.2
Temperature gradient
1.8.3
Humidity
1.8.3.1
Relative Humidity
Operating
0° to 55°C (32° to 131°F)
Nonoperating
–40° to 70°C (–40° to 158°F)
Operating/Nonoperating
20°C/hr (36°F/hour) max, without condensation
Operating
5% to 90% noncondensing (30% per hour max)
Nonoperating