Seagate ST9300553SS Savvio 15K.1 SAS Product Manual - Page 30

Notify Spinup primitive.

Page 30 highlights

Table 3: ST936751SS DC power requirements Voltage Regulation Avg idle current DCX Maximum starting current (peak DC) DC (peak AC) AC Delayed motor start (max) DC Operating current: Typical DCX Maximum DC Maximum (peak) DC Notes [5] [1] [6] 3σ [3] 3σ [3] 3σ [1] [4] [1] 3σ [1] 3σ ST936751SS 1.5 Gbit mode (Amps) (Amps) +5V +12V [2] ±5% ±5% [2] 0.77 0.16 0.85 1.33 1.27 1.87 0.63 0.03 0.75 0.34 0.78 0.38 1.46 1.14 ST936751SS 3.0 Gbit mode (Amps) (Amps) +5V +12V [2] ±5% ±5% [2] 0.74 0.16 0.81 1.28 1.11 1.87 0.67 0.03 0.78 0.34 0.81 0.37 1.52 1.16 [1] Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these values. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient. [2] For +12 V, a -10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 9,936 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been completed and that the drive is able to accept selection by the host initiator. [3] See +12V current profile in Figure 1. [4] This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive. [5] See paragraph 6.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response. [6] During idle, the drive heads are relocated every 60 seconds to a random location within the band from three-quarters to maximum track. General DC power requirement notes. 1. Minimum current loading for each supply voltage is not less than 1.7% of the maximum operating current shown. 2. The +5V and +12V supplies should employ separate ground returns. 3. Where power is provided to multiple drives from a common supply, careful consideration for individual drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak starting current must be available to each device. 4. Parameters, other than spindle start, are measured after a 10-minute warm up. 5. No terminator power. 24 Savvio 15K SAS Product Manual, Rev. C

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

24
Savvio 15K SAS Product Manual, Rev. C
[1]
Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these val-
ues. Power supply at nominal voltage. N (number of drives tested) = 6, 35 Degrees C ambient.
[2]
For +12 V, a –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching
9,936 RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been
completed and that the drive is able to accept selection by the host initiator.
[3]
See +12V current profile in Figure 1.
[4]
This condition occurs after OOB and Speed Negotiation completes but before the drive has received the
Notify Spinup primitive.
[5]
See paragraph 6.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and
transient response.
[6]
During idle, the drive heads are relocated every 60 seconds to a random location within the band from
three-quarters to maximum track.
General DC power requirement notes.
1.
Minimum current loading for each supply voltage is not less than 1.7% of the maximum operating current
shown.
2.
The +5V and +12V supplies should employ separate ground returns.
3.
Where power is provided to multiple drives from a common supply, careful consideration for individual
drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak
starting current must be available to each device.
4.
Parameters, other than spindle start, are measured after a 10-minute warm up.
5.
No terminator power.
Table 3:
ST936751SS
DC power requirements
Notes
ST936751SS
1.5 Gbit mode
ST936751SS
3.0 Gbit mode
(Amps)
(Amps)
(Amps)
(Amps)
Voltage
+5V
+12V [2]
+5V
+12V [2]
Regulation
[5]
±5%
±5% [2]
±5%
±5% [2]
Avg idle current DCX
[1] [6]
0.77
0.16
0.74
0.16
Maximum starting current
(peak DC) DC
3
σ
[3]
0.85
1.33
0.81
1.28
(peak AC) AC
3
σ
[3]
1.27
1.87
1.11
1.87
Delayed motor start (max) DC
3
σ
[1] [4]
0.63
0.03
0.67
0.03
Operating current:
Typical DCX
[1]
0.75
0.34
0.78
0.34
Maximum DC
3
σ
[1]
0.78
0.38
0.81
0.37
Maximum (peak) DC
3
σ
1.46
1.14
1.52
1.16