Sealey SA50 Instruction Manual - Page 2

fig.2, fig.3

Page 2 highlights

4.3.5. Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose diameter should be 1/4" I.D. and fittings must have the same inside dimensions. 4.3.6. Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all connections are secure. 4.4. COUPLINGS Vibration may cause failure if a quick change coupling is connected directly to the needle scaler. To overcome this, connect a leader hose to the needle scaler. A quick change coupling may then be used to connect the leader hose to the air line recoil hose. See fig.2 & 3. fig.2 fig.3 5. OPERATION ‰ 5.1. 5.2. 5.3. WARNING! Ensure you read, understand and apply safety instructions before use. Connect the needle scaler to the air hose as in section 4. To start the scaler, depress the trigger. DO NOT allow the needle scaler to free run for an extended period of time as this will shorten its life. Air flow may also be regulated by the air flow valve at the bottom of the handle (fig.1A). 6. MAINTENANCE ‰ WARNING! Disconnect needle scaler from air supply before changing accessories, servicing or performing maintenance. Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty. Note: Numbers in brackets refer to item numbers in the parts diagram. 6.1. To replace the needles, remove the large cir-clip from the back opening of the main sleeve and loosen the three grub screws. Take hold of the sleeve and press the needles firmly onto a hard surface to ease the plastic retainer out of the sleeve. Remove the hammer followed by the needle supporter, needles and the spring. Remove the old needles from the needle supporter and replace them with a new set. Reassemble the scaling head in the reverse order to that described above. Refer to the parts diagram. Screw the reassembled scaling head back onto the pistol body. 6.2. Lubricate the needle scaler daily with a few drops of Sealey air tool oil dripped into the air inlet. 6.3. Clean the needle scaler after use. 6.4. Loss of power or erratic action may be due to the following: a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose connectors. To remedy check the air supply and follow instructions in Section 4. b) Grit or gum deposits in the needle scaler may also reduce performance. Flush the needle scaler out with gum solvent oil or an equal mixture of SAE No 10 oil and paraffin. Allow to dry before use. 6.5. For a full service contact your local Sealey service agent. 6.6. When not in use, disconnect from air supply, clean needle scaler and store in a safe, dry, childproof location. WARNING! - Risk of Hand Arm Vibration Injury. This tool may cause Hand Arm Vibration Syndrome if its use is not managed adequately. This tool is subject to the vibration testing section of the Machinery Directive 2006/42/EC. This tool is to be operated in accordance with these instructions. Measured vibration emission value (a): 13 m/s² Uncertainty value (k): 5.2 m/s² Please note that the application of the tool to a sole specialist task may produce a different average vibration emission. We recommend that a specific evaluation of the vibration emission is conducted prior to commencing with a specialist task. A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for each tool. NB: Stated Vibration Emission values are type-test values and are intended to be typical. Whilst in use, the actual value will vary considerably from and depend on many factors. Such factors include; the operator, the task and the inserted tool or consumable. NB: ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration. The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand Arm Vibration Syndrome. Health surveillance. We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures can be modified accordingly. Personal protective equipment. We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury that may result from the uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain warm and dry and maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please refer to the Correct Use and Maintenance section in these instructions. Guidance relating to the management of hand arm vibration can be found on the HSC website www.hse.gov.uk - Hand-Arm Vibration at Work. © Jack Sealey Limited Original Language Version SA50.V4 Issue 1 24/12/21

  • 1
  • 2
  • 3

4.3.5.
Line pressure should be increased to compensate for unusually long air hoses (over 8 metres). The minimum hose diameter should be
1/4” I.D. and fittings must have the same inside dimensions.
4.3.6.
Keep hose away from heat, oil and sharp edges. Check hose for wear, and make certain that all connections are secure.
4.4.
COUPLINGS
Vibration may cause failure if a quick change coupling is connected directly to the needle scaler. To overcome this, connect a leader
hose to the needle scaler. A quick change coupling may then be used to connect the leader hose to the air line recoil hose.
See fig.2 & 3.
5. OPERATION
±
WARNING! Ensure you read, understand and apply safety instructions before use.
5.1.
Connect the needle scaler to the air hose as in section 4.
5.2.
To start the scaler, depress the trigger.
DO NOT
allow the needle scaler to free run for an extended period of time as this will
shorten its life.
5.3.
Air flow may also be regulated by the air flow valve at the bottom of the handle (fig.1A).
6. MAINTENANCE
±
WARNING!
Disconnect needle scaler from air supply before changing accessories, servicing or performing maintenance. Replace or
repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
Note:
Numbers in brackets refer to item numbers in the parts diagram.
6.1.
To replace the needles, remove the large cir-clip from the back opening of the main sleeve and loosen the three grub screws. Take
hold of the sleeve and press the needles firmly onto a hard surface to ease the plastic retainer out of the sleeve. Remove the
hammer followed by the needle supporter, needles and the spring. Remove the old needles from the needle supporter and replace
them with a new set. Reassemble the scaling head in the reverse order to that described above. Refer to the parts diagram. Screw
the reassembled scaling head back onto the pistol body.
6.2.
Lubricate the needle scaler daily with a few drops of Sealey air tool oil dripped into the air inlet.
6.3.
Clean the needle scaler after use.
6.4.
Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose connectors. To remedy
check the air supply and follow instructions in Section 4.
b) Grit or gum deposits in the needle scaler may also reduce performance. Flush the needle scaler out with gum solvent oil
or an equal mixture of SAE No 10 oil and paraffin. Allow to dry before use.
6.5.
For a full service contact your local Sealey service agent.
6.6.
When not in use, disconnect from air supply, clean needle scaler and store in a safe, dry, childproof location.
WARNING! – Risk of Hand Arm Vibration Injury.
This tool may cause Hand Arm Vibration Syndrome if its use is not managed adequately.
This tool is subject to the vibration testing section of the Machinery Directive 2006/42/EC.
This tool is to be operated in accordance with these instructions.
Measured vibration emission value (a): 13 m/s²
Uncertainty value (k): 5.2 m/s²
Please note that the application of the tool to a sole specialist task may produce a different average vibration emission. We recommend that a
specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.
A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for each tool.
NB:
Stated Vibration Emission values are type-test values and are intended to be typical.
Whilst in use, the actual value will vary considerably from and depend on many factors.
Such factors include; the operator, the task and the inserted tool or consumable.
NB:
ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration.
The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of Hand Arm Vibration
Syndrome.
Health surveillance.
We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures can be
modified accordingly.
Personal protective equipment.
We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury that may result from the
uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain warm and dry and
maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please refer to the Correct Use and
Maintenance section in these instructions. Guidance relating to the management of hand arm vibration can be found on the HSC website
www.hse.gov.uk - Hand-Arm Vibration at Work.
fig.2
fig.3
Original Language Version
© Jack Sealey Limited
SA50.V4 Issue 1 24/12/21