Sennheiser SKP 500 G4 Instruction manual ew 500 P G4 PDF - Page 68
Advanced -> Sync Settings menu item
![]() |
View all Sennheiser SKP 500 G4 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 68 highlights
Using the EK 500 G4 Advanced -> Sync Settings menu item In the Sync Settings menu item of the Advanced submenu, you can configure the parameters to be sent to the transmitters and activate or deactivate transmission The parameters are defined separately for the SK, SKM and SKP. You can activate/deactivate the following parameters: • Sensitivity • Auto Lock • Mute Mode • RF Power • Phantom Power 48 V (only SKP 500 G4) To configure a parameter and activate or deactivate transmission: ▷ Go to the parameter in question in the Advanced -> Sync Settings menu. ▷ Press the SET button to open the sub-item. ▷ Press the UP and DOWN buttons to set the value. ▷ Press the SET button to save the setting. ▷ Press the UP and DOWN buttons to activate or deactivate the check box. When the check box is activated, the value will be transmitted during synchronization. If it is deactivated, the value will not be transmitted. ▷ Press the SET button to save the setting. 67
![](/manual_guide/products/sennheiser-ew-500-film-g4-instruction-manual-ew-500-p-g4-pdf-b1c51bf/68.png)