Sharp AF-P80CX AF-P80CX Operation Manual

Sharp AF-P80CX Manual

Sharp AF-P80CX manual content summary:

  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 1
    AF-P80CX ROOM AIR CONDITIONER INSTALLATION AND OPERATION MANUAL CONTENTS PAGE FOR YOUR PROTECTION 2 CONSUMER LIMITED WARRANTY ..... 3 INSTALLATION INSTRUCTIONS • CHECK WINDOW AREA 4 • LOCATlON 4 • ACCESSORIES 5 • SUGGESTED TOOLS 5 • INSTALLATION 6 PRECAUTIONS • CAUTION FOR USE 8 •
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 2
    PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 Please provide
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 3
    Number & Description: AF-P80CX Room Air Conditioner. Be sure to have this information available when you need service for your Product. Sharp Authorized Servicer, call Sharp Toll Free at 1-800-BE-SHARP. Contact your Sharp Authorized Servicer to obtain in-home service for this Product. The Servicer
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 4
    Before beginning installation, read these instructions carefully. Use the enclosed MOUNTING KIT for repairs, replacement and secure positioning, make sure foundation is solid and level. • The room air conditioner must be installed in an area within reach of a properly rated grounded outlet. •
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 5
    IINNSSTTAALLLLAATTIIOONN IINNSSTTRRUUCCTTIIOONNSS ACCESSORIES No. Accessories Q'ty 1 Right closure assembly 1 2 Left closure assembly 1 3 Window sash foam seal 1 4 Window sash foam seal (adhesive type) 1 5 Bottom gasket 1 6 Screws (L=1", 25.4mm) 7 7 Screws (L= 13/32", 10mm) 6 8
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 6
    INSTALLATION INSTRUCTIONS INSTALLATION WARNING: Make sure the unit is turned off and of the provided screws. (L= 13/32", 10mm) Closure assembly 3 Open the window sash and place the air conditioner on the sill. Balance the unit on the sill and close the window sash securely behind the top angle
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 7
    INSTALLATION INSTRUCTIONS 5 Insert the closure assemblies on both sides into the rails of the jamb. Jamb (Left) Closure assembly (Left) Sill 6 Loosen screws on both sides of
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 8
    PRECAUTIONS CAUTION FOR USE IMPORTANT: Points to keep in mind when using your air conditioner. • Install the air conditioner by following the installation instructions given in the previous section of this manual. • Make sure the unit is the correct capacity for the area you want to cool. • Do
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 9
    power was off for less than three minutes, be sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three minutes, a protective device in the unit may cause the compressor to shut off. This protective device will prevent cooling for about 5 minutes
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 10
    HOW TO OPERATE PARTS NAMES UNIT 3 4 5 2 1 6 11 1Front Cabinet 7 2Air Inlet (Indoor Side) 3Horizontal Louvers 4Vertical Louvers 8 5Air Outlet (Indoor Side) 6Control Panel 7Rear Cabinet 9 8Air Inlet (Outdoor side) 9Filter (Pull the filter handle 10 to the right to remove.) 0Filter
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 11
    COOLING OPERATION HOW TO OPERATE SELECTOR indicator POWER indicator F hr COOL / FAN TEMP SELECTOR TIMER ENERGY ON/OFF SAVER POWER ON/OFF POWER ON/OFF pad 1 Touch POWER ON/OFF pad. • The unit is preset at 74°F and HIGH COOL. This will show in the display when the power is first turned on. •
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 12
    HOW TO OPERATE TO CHANGE FAN SPEED AND OPERATION MODE SELECTOR indicator F hr COOL / FAN TEMP SELECTOR TIMER ENERGY ON/OFF SAVER POWER ON/OFF SELECTOR pad During operation Touch SELECTOR pad and select the operation mode and fan speed. • SELECTOR indicator and display will light in order as
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 13
    indicator will go off. NOTE: ENERGY SAVER cannot be set during fan only (HIGH FAN, MED FAN, LOW FAN) operation. TO CHANGE AIR FLOW DIRECTION The horizontal louvers are used to adjust the UP / DOWN direction of air flow, and the vertical louvers are used to adjust the LEFT / RIGHT direction of
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 14
    HOW TO OPERATE ON TIMER OPERATION • This unit has a built-in timer that can be programmed to start the unit up to 12 hours in advance. You can set the timer to start in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the start time, or in 1 hour increments from 10 to 12 hours in
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 15
    HOW TO OPERATE OFF TIMER OPERATION • This unit has a built-in timer that can be programmed to shut the unit off up to 12 hours in advance. You can set the timer to stop in increments of 30 minutes (0.5 hours) up to 9.5 hours in advance of the stop time, or in 1 hour increments from 10 to 12 hours
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 16
    HOW TO OPERATE USING THE REMOTE CONTROL INSTALLING BATTERIES Use two AA (R6) batteries. 1 Remove the battery compartment cover. 2 Insert the batteries in the compartment, making sure the and polarities are properly aligned. 3 Replace the cover. Battery compartment cover NOTES: • The battery life
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 17
    HOW TO OPERATE OPERATING WITH THE REMOTE CONTROL TRANSMITTER PLASMACLUSTER button (See page 18) ON / OFF TEMP. SELECTOR SET TIMER / OFF POWER ON / OFF TEMPERATURE setting button TEMP. ---Raise temp. setting 1°F at a time. TEMP. ---Lower temp. setting 1°F at a time. SELECTOR button Push to change
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 18
    HOW TO OPERATE PLASMACLUSTER OPERATION Cluster ions are released into the room, keeping air your room clean. PLASMACLUSTER button During operation 1 Press PLASMACLUSTER button. • PLASMACLUSTER indicator will light. ON / OFF TEMP. SELECTOR SET TIMER / OFF POWER ON / OFF PLASMACLUSTER
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 19
    HOW TO OPERATE NOTE FOR PLASMACLUSTER OPERATION The ionizer inside the air conditioner will discharge cluster ions, which are collective mass of positive and negative ions, into the room. The cluster ions reduce airborne mold fungus and deodorize/
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 20
    CLEANING AND MAINTENANCE CLEANING THE FILTER If the filter is clogged with dust, the amount of air flow will be reduced, resulting in poor cooling performance. The filter should be cleaned every 10 days. At the beginning of every cooling season or
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 21
    , PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE. AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the unit cooling coils to freeze. If this happens, clean the filter and replace. Run the air conditioner on the MED FAN setting until all ice dissipates. • Is the temperature set properly
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 22
    BEFORE CALLING FOR SERVlCE TIMER DOES NOT WORK PROPERLY • If a power failure occurs while the ON or OFF TIMER is set, the TIMER setting will be cancelled and will not resume even after the power is reinstated. This is the normal operation for this unit. NOTE: WATER IN BOTTOM OF TRAY • Water will
  • Sharp AF-P80CX | AF-P80CX Operation Manual - Page 23
    SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 SHARP CORPORATION Osaka, Japan Printed in Thailand TINSEA318JBRZ 02AO TL 1
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

AF-P80CX
ROOM AIR CONDITIONER
INSTALLATION AND OPERATION
MANUAL
PAGE
CONTENTS
This INSTALLATION AND OPERATION
MANUAL explains the proper use of your
new
Sharp Air Conditioner. Read these instructions
carefully before installing
or operating
your air
conditioner. The INSTALLATION
AND
OP-
ERATION
MANUAL
should be kept in a safe
place for handy reference.
FOR YOUR PROTECTION
....................
2
CONSUMER LIMITED WARRANTY
.....
3
INSTALLATION INSTRUCTIONS
• CHECK WINDOW AREA
........................
4
• LOCATlON
..............................................
4
• ACCESSORIES
......................................
5
• SUGGESTED TOOLS
............................
5
• INSTALLATION
.......................................
6
PRECAUTIONS
CAUTION FOR USE
............................
8
• GROUNDING INSTRUCTIONS
...........
8
• NOTES ON OPERATION
....................
9
• ENERGY EFFICIENCY TIPS
...............
9
HOW TO OPERATE
PARTS NAMES
...................................
10
COOLING OPERATION
......................
11
TO CHANGE TEMPERATURE SETTING
..........
11
TO CHANGE FAN SPEED AND OPERATION MODE ..
12
• ENERGY SAVER
.................................
13
TO CHANGE AIR FLOW DIRECTION
.......
13
• ON TIMER OPERATION
.....................
14
• OFF TIMER OPERATION
....................
15
• USING THE REMOTE CONTROL
.......
16
• PLASMACLUSTER OPERATION
........
18
CLEANING AND MAINTENANCE
........
20
BEFORE CALLING FOR SERVlCE
......
21
As an ENERGY STAR Partner, Sharp Electronics has determined that this products (AF-P80CX) meet the
ENERGY STAR guidelines for energy efficient air conditioners.
To meet these guidelines, air conditioners
must be at least 10% more efficient than the minimum Federal standard.