Misfeed in the copier
UPC - 074000072954
View all Sharp AL-840 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
MISFEED REMOVAL 3 Straighten the edges of the stack of paper and then reinsert it into the paper tray. 4 Push the paper release lever back again to secure the paper. B. Misfeed in the copier 1 Place some scrap paper on a nearby level surface. 2 Push gently on both sides of the front cover to open the cover. 6 Copier trouble? 3 Gently pull the TD cartridge out and place it on the scrap paper which was prepared in step 1. To remove the TD cartridge, see page 28, step 3. 4 Take a piece of scrap paper that is larger than the drum cartridge and fold it in half. Keep this paper ready to shield the light-sensitive part of the drum cartridge from light after it is removed from the copier. q The paper to be used for placing the TD cartridge and drum cartridge may become soiled due to toner, etc. q The paper for placing the drum cartridge must be large enough to cover the surface of the cartridge (green portion) when folded in half. 5 Gently pull the drum cartridge out and wrap the removed drum cartridge in the paper which was prepared in step 4 so that the green drum section is shielded from light. Place the drum cartridge down on a level surface. To remove the drum cartridge, see page 29, DRUM CARTRIDGE REPLACEMENT. 35