Sharp ER-A520 ER-A520 ER-A530 Operation Manual - Page 121
Commission groups
View all Sharp ER-A520 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 121 highlights
Commission groups PGM 2 2215 2235 You can assign PLUs/UPCs to commission groups (1 to 9). Direct 2065 (Dynamic UPC file) Procedure For each PLU/UPC . @ 2215 2065 PLU code (max. 5 digits) UPC code (6 to 13 digits) To program any PLU/UPC Ä To program zero @ Commission group (0 - 9, 0: non commision) t To program for the following PLU/UPC Ç For a range of PLUs . @ 2235 To apply the current setting of start PLU code to PLUs within the range Start PLU code (max. 5 digits) @ End PLU code (max. 5 digits) @ Commission group (0 - 9, 0:non commision) t Ç Note For a range of PLUs: PLU codes must have already been defined. If not, an error message "NO RECORD" will appear on the display. Example Programming the commission group 1 for PLU 1 For each PLU/UPC Key operation 2215 . @ 1@1t Ç Print Commission group no. Programming all of PLU 11 thru 20 for the commission group 1 For a range Key operation Print of PLUs 2235 . @ 11 @ 20 @ 1 t Ç 119