Sharp FP-P35CX FP-P35CX Operation Manual - Page 10
Operation
![]() |
UPC - 074000662179
View all Sharp FP-P35CX manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
OPERATION MAIN UNIT OPERATION Clean Filter Indicator Light Clean Sign Light Main Unit Controls • AUTO • QUICK CLEAN • POLLEN • SILENT • MEDIUM • MAX MODE Selection Button Power ON/OFF Button 1 Power ON/OFF Button • Used to start operation (short beep) and stop operation (long beep) • Fan Speed Indicator Light turn on/off. • Unless the power cord is unplugged, the operation starts in the previous mode the unit was operated in. 2 MODE Selection Button • The operation mode can be switched. AUTO operation The fan speed is automatically switched (HIGH*, MEDIUM, SILENT) depending on the amount of impurities in the air. The sensor detect the impurities for efficient air purification. QUICK CLEAN operation The unit will operate at HIGH* fan speed for 15 minutes, then will operate at Auto operation. The operation mode is effective when quick removal of impurities in the air is desired. POLLEN mode operation The unit will operate at HIGH* fan speed for 10 minutes, then will alternate between MEDIUM and HIGH* for 20 minutes. 10 minutes: HIGH fan speed 20 minutes: MEDIUM fan speed 20 minutes: HIGH fan speed MAX operation The unit will operate at a fan speed of MAX. MEDIUM operation The unit will operate at a fan speed of MEDIUM. SILENT operation The unit will operate quietly using minimal air intake. * HIGH fan speed is an intermediate speed between MEDIUM and MAX. E-8