Connect Wiring, Prepare The Hood

Page 8 highlights

PREPARE THE HOOD Non-Ducted Installations Only: Requires a Performance Ring to be attached to the blower wheel. The Performance Ring is packed behind the Teflon®Coated Bottom Cover. To install ring: 1. Remove Retaining Ring using a flat blade screwdriver. Set aside for later. Remove the Blower Wheel by rocking it side to side and applying a slight force to pull wheel from motor. Turn the Blower Wheel over. 2. Slide the Performance Ring onto the Small Diameter End of the blower wheel and down to the Stop Edge of the wheel. 3. Reassemble wheel to motor. Make sure Tab on wheel fits into one of the Motor Slots. 4. Push wheel down until it is locked in place. Replace Retaining Ring from Step 1. Be sure it is within the upper and lower tabs. 5. Check that wheel is properly positioned as shown. Press Sections into place if necessary. Make sure wheel turns freely. Note: For information on non-ducted filters, see page 9. BLOWER RETAINING RING WHEEL TAB SMALL DIAMETER END SECTIONS STOP EDGE MOTOR SLOTS PERFORMANCE RING CONNECT WIRING WARNING To reduce the risk of electric shock, make sure power is switched off at the service panel. Lock or tag service panel to prevent power from being switched on accidentally. 1 Connect House Wiring (120 VAC) to hood. Use a piece of cardboard to protect the cooktop, if necessary. 2 Connect house black to hood black wire, house white to hood white wire and house ground under Green Ground Screw. Securely tighten cable clamp onto house wiring. 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

WARNING
To reduce the risk of electric shock, make
sure power is switched off at the service panel. Lock or
tag service panel to prevent power from being switched
on accidentally.
1
Connect
House Wiring
(120 VAC) to hood. Use a piece
of
cardboard
to protect the cooktop, if necessary.
2
Connect house black to hood black wire, house white to
hood white wire and house ground under
Green Ground
Screw
. Securely tighten cable clamp onto house wiring.
8
CONNECT WIRING
Non-Ducted Installations Only:
Requires a
Performance Ring
to be attached to the blower
wheel. The
Performance Ring
is packed behind the Teflon
®
-
Coated Bottom Cover.
To install ring:
1.
Remove
Retaining Ring
using a flat blade screwdriver.
Set aside for later. Remove the
Blower Wheel
by rocking
it side to side and applying a slight force to pull wheel
from motor. Turn the Blower Wheel over.
2
. Slide the
Performance Ring
onto the
Small Diameter
End
of the blower wheel and down to the
Stop Edge
of
the wheel.
3.
Reassemble wheel to motor. Make sure
Tab
on wheel
fits into one of the
Motor Slots
.
4
. Push wheel down until it is locked in place. Replace
Retaining Ring
from Step 1. Be sure it is within the
upper and lower tabs.
PREPARE THE HOOD
BLOWER
WHEEL
TAB
SECTIONS
SMALL DIAMETER
END
STOP
EDGE
PERFORMANCE RING
MOTOR SLOTS
RETAINING RING
5.
Check that wheel is properly positioned as shown.
Press
Sections
into place if necessary. Make sure wheel
turns freely.
Note:
For information on non-ducted filters, see page 9.