Specifications Model PN-Y556 PN-Y496 PN-Y436 PN-Y326 Power requirement AC 100 - 240 V, 1.2 A, 50/60 Hz AC 100 - 240 V, 1.0 A, 50/60 Hz AC 100 - 240 V, 0.9 A, 50/60 Hz AC 100 - 240 V, 0.8 A, 50/60 Hz Operating temperature * 32°F to 104°F (0°C to 40°C) Operating humidity 20% to 80% (no condensation) Power consumption 105 W 87 W 76 W 69 W Dimensions (excluding protrusions) Approx. 48-9/16 (W) x Approx. 43-3/16 (W) x Approx. 38 (W) x Approx. 28-1/2 (W) x inch (mm) 1-13/16 (D) x 1-13/16 (D) x 1-13/16 (D) x 2-3/16 (D) x 27-15/16 (H) 24-15/16 (H) 22 (H) 16-11/16 (H) (1233.0 x 46.0 x 710.0) (1097.0 x 46.0 x 634.0) (965.0 x 46.0 x 559.0) (724.5 x 56.0 x 424.0) Weight Approx. 54.0 (24.5) Approx. 44.1 (20.0) Approx. 33.1 (15.0) Approx. 19.8 (9.0) lbs. (kg) * Temperature condition may change when using the monitor together with the optional equipments recommended by SHARP. In such cases, please check the temperature condition specified by the optional equipments. As a part of our policy of continuous improvement, SHARP reserves the right to make design and specification changes for product improvement without prior notice. The performance specification figures indicated are nominal values of production units. There may be some deviations from these values in individual units. Mounting Precautions (For SHARP dealers and service engineers) • When installing, removing or moving the monitor, ensure that this is carried out by at least 2 people. • Be sure to use a wall-mount bracket designed or designated for mounting the monitor. • To attach a VESA-compliant mounting bracket, use M6 screws that are 5/16 inch (8 mm) to 3/8 inch (10 mm) longer than the thickness of the mounting bracket. 5/16 - 3/8 inch (8-10 mm) Screws (M6) Mounting bracket Monitor mounting • This monitor is designed to be installed on a concrete wall or pillar. Reinforced work might be necessary for some materials such as plaster / thin plastic board / wood before starting installation. • This monitor and bracket must be installed on a wall which can endure at least 4 times or more the weight of the monitor. Install by the most suitable method for the material and the structure. • Do not use an impact driver. • When moving the monitor, hold the parts marked by below. Do not hold the LCD panel. This may cause product damage, failure, or injury. • After mounting, please carefully ensure the monitor is secure, and not able to come loose from the wall or mount. • Do not use any screw holes other than VESA holes for installation. • If you will use the monitor in a flat installation (tilted more than 20° (upward or downward) from a perpendicular state with respect to the horizontal plane), please contact customer service. Special installation conditions apply in a flat installation. E8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

8
E
When installing, removing or moving the monitor, ensure that this is carried out by at least 2 people.
Be sure to use a wall-mount bracket designed or designated for mounting the monitor.
To attach a VESA-compliant mounting bracket, use M6 screws that are 5/16 inch (8 mm) to 3/8 inch (10 mm) longer than the
thickness of the mounting bracket.
Screws (M6)
Mounting bracket
Monitor mounting
5/16 - 3/8 inch (8-10 mm)
This monitor is designed to be installed on a concrete wall or pillar. Reinforced work might be necessary for some materials
such as plaster / thin plastic board / wood before starting installation.
This monitor and bracket must be installed on a wall which can endure at least 4 times or more the weight of the monitor.
Install by the most suitable method for the material and the structure.
Do not use an impact driver.
When moving the monitor, hold the parts marked by
below. Do not hold the LCD panel. This may cause product
damage, failure, or injury.
After mounting, please carefully ensure the monitor is secure, and not able to come loose from the wall or mount.
Do not use any screw holes other than VESA holes for installation.
If you will use the monitor in a flat installation (tilted more than 20° (upward or downward) from a perpendicular state with
respect to the horizontal plane), please contact customer service. Special installation conditions apply in a flat installation.
Model
PN-Y556
PN-Y496
PN-Y436
PN-Y326
Power requirement
AC 100 - 240 V,
1.2
A, 50/60 Hz
AC 100 - 240 V,
1.0
A, 50/60 Hz
AC 100 - 240 V,
0.9
A, 50/60 Hz
AC 100 - 240 V,
0.8 A, 50/60 Hz
Operating temperature *
32°F to 104°F (0°C to 40°C)
Operating humidity
20% to 80% (no condensation)
Power consumption
105 W
87 W
76 W
69 W
Dimensions (excluding protrusions)
inch (mm)
Approx.
48-9/16
(W) x
1-13/16 (D) x
27-15/16 (H)
(1233.0 x 46.0 x 710.0)
Approx. 43-3/16 (W) x
1-13/16
(D) x
24-15/16 (H)
(
1097.0 x 46.0 x 634.0
)
Approx. 38 (W) x
1-13
/16 (D) x
22 (H)
(96
5.0 x 46.0
x 559.0)
Approx. 28-1/2 (W) x
2-3/16 (D) x
16-11/16 (H)
(724.5 x 56.0 x 424.0)
Weight
lbs. (kg)
Approx.
54.0 (24.5)
Approx. 44.1 (20.0)
Approx.
33.1 (15.0)
Approx. 19.8 (9.0)
* Temperature condition may change when using the monitor together with the optional equipments recommended by SHARP. In such cases,
please check the temperature condition specified by the optional equipments.
As a part of our policy of continuous improvement, SHARP reserves the right to make design and specification changes for product improvement
without prior notice. The performance specification figures indicated are nominal values of production units. There may be some deviations from
these values in individual units.
Specifications
Mounting Precautions (For SHARP dealers and service engineers)