Sharp R-22JT Service Guide - Page 15
Available output current in our 1:20, The high voltage doubler circuit will
![]() |
View all Sharp R-22JT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Transformers Primary •Secondary current is inversely proportional to the turns ratio •Available output current in our 1:20 step up transformer will be 20x less than the current on the primary Input= 8 amps Secondary Output= 400 ma •The high voltage doubler circuit will double the transformer secondary voltage to 4800 volts with an output current between 300ma and 450ma •This 2400volt potential at 300ma is enough to kill you if came into contact with it.
![](/manual_guide/products/sharp-r22jt-service-guide-0e17027/15.png)
Transformers
•
Secondary current is inversely
proportional to the turns ratio
•
Available output current in our 1:20
step up transformer will be 20x less
than the current on the primary
•
The high voltage doubler circuit will
double the transformer secondary
voltage to 4800 volts with an output
current between 300ma and 450ma
•
This 2400volt potential at 300ma is
enough to kill you if came into contact
with it.
Primary
Secondary
Input=
8 amps
Output=
400 ma