Sharp R-22JT Service Guide - Page 96
Replace control PWB if there is
View all Sharp R-22JT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 96 highlights
Troubleshooting EE1 and EE2 Relay 1 Relay 2 7. Check the primary interlock relays. Connect AC power cord to wall outlet Start cook process and measure for continuity across primary interlock relays 1 and 2 Note: "EE3" will appear on display after 9 seconds Replace control PWB if there is no continuity at any of the 2 relays.
Connect AC power cord to wall
outlet
Start cook process and measure
for continuity across primary
interlock relays 1 and 2
Note: “EE3” will appear on
display after 9 seconds
Replace control PWB if there is
no continuity at any of the 2
relays.
Relay 1
Relay 2
Troubleshooting EE1 and EE2
7.
Check the primary interlock
relays.