ALARM Setting Command List, Command Set, Command, Comments, VISCA Mode Code pp, Details of Mode

Page 18 highlights

ALARM Setting Command List Command Set CAM _ Alarm Command On Off Set Mode Set Day Night Level Command Packet 8x 01 04 6B 02 FF 8x 01 04 6B 03 FF 8x 01 04 6C pp FF 8x 01 04 6D 0p 0p 0p 0q 0q 0q FF Basic Functions Comments Alarm start Alarm stop Mode Setting *Select one from 13 modes ppp: Day distinction AE level qqq: Night distinction AE level. 90 07 04 6B 01 FF 90 07 04 6B 00 FF High signal output (Low t High edge) Low signal output (High t Low edge) VISCA Mode Code (pp) Details of Mode 00 Set the internal focus position. When focus movement is detected, the detect signal is High. When focus goes back to the previous position, the detect signal is Low. 01 Set a fixed period of time. When focus does not move during the time, the focus position is memorized as a rest position and the detect signal is Low. When focus moves, the detect signal is High. Afterwards when focus does not move for the fixed period of time, the focus position is memorized and the detect signal becomes Low. 02 Set the internal AE Level. When AE movement is detected, the detect signal is High. When AE Level goes back to the previous level, the detect signal is Low. 03 Set a fixed period of time. When AE Level does not change during this time, the AE value is memorized as a rest value and the detect signal is Low. When AE value changes, the detect signal is High. Afterwards when AE value does not change for the fixed period of time, the AE value is memorized and the detect signal becomes Low. 04 mode "00" and mode "02" 05 mode "00" and mode "03" 06 mode "01" and mode "02" 07 mode "01" and mode "03" 08 mode "00" or mode "02" 09 mode "00" or mode "03" 0A mode "01" or mode "02" 0B mode "01" or mode "03" 0C Day-Night Mode ALARM Inquiry Command List Inquiry Command CAM _ Alarm Inq CAM _ Alarm Mode Inq CAM_AlarmDayNightLevel Inq Command Packet Inquiry Packet 8x 09 04 6B FF y0 50 02 FF y0 50 03 FF 8x 09 04 6C FF y0 50 pp FF 8x 09 04 6D FF y0 50 0p 0p 0p 0q 0q 0q 0r 0r 0r FF CAM_AlarmDetLevelInq 8x 09 04 6E FF y0 50 01 FF y0 50 00 FF Comments On Off pp: Alarm Mode ppp: Day setting AE Level qqq; Night setting AE Level rrr: Now AE Level Detect Level is High. Detect Level is Low. 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

18
Basic Functions
ALARM Setting Command List
ALARM Inquiry Command List
Command Set
Command
Command Packet
Comments
CAM _ Alarm
On
8x 01 04 6B 02 FF
Alarm start
Off
8x 01 04 6B 03 FF
Alarm stop
Set Mode
8x 01 04 6C pp FF
Mode Setting
*Select one from 13 modes
Set Day Night Level
8x 01 04 6D 0p 0p 0p
ppp: Day distinction AE level
0q 0q 0q FF
qqq: Night distinction AE level.
90 07 04 6B 01 FF
High signal output
(Low
t
High edge)
90 07 04 6B 00 FF
Low signal output
(High
t
Low edge)
VISCA Mode Code (pp)
Details of Mode
00
Set the internal focus position. When focus movement is detected, the detect signal is High. When focus goes
back to the previous position, the detect signal is Low.
01
Set a fixed period of time. When focus does not move during the time, the focus position is memorized as a
rest position and the detect signal is Low.
When focus moves, the detect signal is High. Afterwards when focus does not move for the fixed period of
time, the focus position is memorized and the detect signal becomes Low.
02
Set the internal AE Level. When AE movement is detected, the detect signal is High. When AE Level goes
back to the previous level, the detect signal is Low.
03
Set a fixed period of time. When AE Level does not change during this time, the AE value is memorized as a
rest value and the detect signal is Low.
When AE value changes, the detect signal is High.
Afterwards when AE value does not change for the fixed period of time, the AE value is memorized and the
detect signal becomes Low.
04
mode “00” and mode “02”
05
mode “00” and mode “03”
06
mode “01” and mode “02”
07
mode “01” and mode “03”
08
mode “00” or mode “02”
09
mode “00” or mode “03”
0A
mode “01” or mode “02”
0B
mode “01” or mode “03”
0C
Day-Night Mode
Inquiry Command
Command Packet
Inquiry Packet
Comments
CAM _ Alarm Inq
8x 09 04 6B FF
y0 50 02 FF
On
y0 50 03 FF
Off
CAM _ Alarm Mode Inq
8x 09 04 6C FF
y0 50 pp FF
pp: Alarm Mode
CAM_AlarmDayNightLevel Inq
8x 09 04 6D FF
y0 50 0p 0p 0p
ppp: Day setting AE Level
0q 0q 0q 0r 0r 0r FF
qqq; Night setting AE Level
rrr: Now AE Level
CAM_AlarmDetLevelInq
8x 09 04 6E FF
y0 50 01
FF
Detect Level is High.
y0 50 00
FF
Detect Level is Low.