Sony FCBEX980 User Manual (FCB-EX980_series_Technical_Manual ) - Page 29

Eclipse, Eclipse of the Lens, Spectral Sensitivity Characteristics, Vibration Specifications - fcb ex980p

Page 29 highlights

Eclipse When designing the housing, refer to the dimensional allowance as shown in the figure below. Basic Functions Spectral Sensitivity Characteristics FCB-EX980S/EX980SP 10.68 13.13 (30) 28.1˚ 12.9˚ FCB-EX980/EX980P Eclipse of the Lens The eclipse phenomenon occurs with the FCB-980/ 980P. This is because a sufficient amount of aperture is not available due to the CCD size and the lens structure of the FCB-980/980P. However, it has been verified that the eclipse will not be visible in the case of a more than 90 % effective image. For your reference, see the following diagram. B/20=5% A/20=5% B/20=5% A A/20=5% B : Normal scan display area : Under scan display area Vibration Specifications Test Method (Random vibration) • Fix the camera at the four fixation points of the base using M2 screws. • Perform the random vibration test under the following conditions in the X, Y and Z directions for 20 minutes in each direction. • The camera vibration specification is to have no malfunction after this test. Power spectrum density 5 to 50 Hz 4.14 m2/s3 {0.043 G2/Hz} 50 to 100 Hz -36 dB/oct Effective overall value 14.3 m/s2 {1.46 G} Test time 20 minutes 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61

29
Basic Functions
Spectral Sensitivity
Characteristics
FCB-EX980S/EX980SP
Vibration
Specifications
Test Method (Random vibration)
• Fix the camera at the four fixation points of the base
using M2 screws.
• Perform the random vibration test under the
following conditions in the X, Y and Z directions for
20 minutes in each direction.
• The camera vibration specification is to have no
malfunction after this test.
Power spectrum density
Effective overall value
Test time
5 to 50 Hz
4.14 m
2
/s
3
{0.043 G
2
/Hz}
50 to 100 Hz
–36 dB/oct
14.3 m/s
2
{1.46 G}
20 minutes
Eclipse
When designing the housing, refer to the dimensional
allowance as shown in the figure below.
FCB-EX980/EX980P
10.68
28.1˚
13.13
(
30
)
12.9˚
B/20=5%
B/20=5%
A
B
A/20=5%
A/20=5%
Eclipse of the Lens
The eclipse phenomenon occurs with the FCB-980/
980P. This is because a sufficient amount of aperture is
not available due to the CCD size and the lens
structure of the FCB-980/980P. However, it has been
verified that the eclipse will not be visible in the case
of a more than 90 % effective image.
For your reference, see the following diagram.
: Normal scan display area
: Under scan display area