Sony FCBIX47CP Product Manual (Color Camera Module - Technical Manual) - Page 39

VISCA Device Setting, Command, For VISCA Network Administration, VISCA Interface Command

Page 39 highlights

VISCA Device Setting Command Before starting control of the FCB camera, be sure to send the Address command and the IF_Clear command using the broadcast function. For VISCA Network Administration ● Address Sets an address of a peripheral device. Use when initializing the network and when receiving the network change message indicated below. ● Network Change Sent from the peripheral device to the controller when a device is removed from or added to the network. The address must be re-set when this message is received. Packet Address 88 30 01 FF Network Change X0 38 FF X = 9 to F: FCB camera address + 8 Note Always broadcasted. Command List VISCA Interface and Inquiry ● IF_DeviceTypeInq Returns information on the VISCA interface. Inquiry IF_DeviceTypeInq Inquiry Packet 8X 09 00 02 FF Reply Packet Description Y0 50 GG GG HH GGGG = Vender ID HH JJ JJ KK FF (0020: Sony) HHHH = Model ID 043C=FCB-IX47C 043D=FCB-IX47CP 043E=FCB-IX45C 043F=FCB-IX45CP JJJJ = ROM revision KK = Maximum socket # (02) X = 1 to 7: FCB camera address (For inquiry packet) X = 9 to F: FCB camera address +8 (For reply packet) VISCA Interface Command ● IF_Clear Clears the command buffers in the FCB camera and cancels the command currently being executed. Command Packet Reply Packet Note IF_Clear 8X 01 00 01FF X0 50 FF IF_Clear (broadcast) 88 01 00 01 FF 88 01 00 01 FF X = 1 to 7: FCB camera address (For inquiry packet) X = 9 to F: FCB camera address +8 (For reply packet) 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59

39
Command List
VISCA Device Setting
Command
Before starting control of the FCB camera, be sure to
send the Address command and the IF_Clear
command using the broadcast function.
For VISCA Network Administration
Address
Sets an address of a peripheral device. Use when
initializing the network and when receiving the
network change message indicated below.
Network Change
Sent from the peripheral device to the controller
when a device is removed from or added to the
network. The address must be re-set when this
message is received.
Packet
Note
Address
88 30 01 FF
Always broadcasted.
Network Change
X0 38 FF
X = 9 to F: FCB camera address + 8
VISCA Interface Command
IF_Clear
Clears the command buffers in the FCB camera and
cancels the command currently being executed.
Command Packet Reply Packet
Note
IF_Clear
8X 01 00 01FF
X0 50 FF
IF_Clear (broadcast)
88 01 00 01 FF
88 01 00 01 FF
X = 1 to 7: FCB camera address (For inquiry packet)
X = 9 to F: FCB camera address +8 (For reply packet)
VISCA Interface and Inquiry
IF_DeviceTypeInq
Returns information on the VISCA interface.
Inquiry
Inquiry Packet
Reply Packet
Description
IF_DeviceTypeInq
8X 09 00 02 FF
Y0 50 GG GG HH
GGGG = Vender ID
HH JJ JJ KK FF
(0020: Sony)
HHHH = Model ID
043C=FCB-IX47C
043D=FCB-IX47CP
043E=FCB-IX45C
043F=FCB-IX45CP
JJJJ = ROM revision
KK = Maximum socket # (02)
X = 1 to 7: FCB camera address (For inquiry packet)
X = 9 to F: FCB camera address +8 (For reply packet)