Sony PVM-X1800 Operating Instructions - Page 9

About error/warning signals of the indicator, About operations using the Sony monitor control

Page 9 highlights

About error/warning signals of the indicator While the unit is in use, the  (Power) switch indicator or CAUTION indicator of the front panel may show error or warning signals. If an error display appears, refer to Sony qualified service personnel. Error display CAUTION indicator - - Power indicator Symptom Flashes in red (every second) Power abnormality, circuit board abnormality, sensor abnormality Flashes in red (every two seconds) Fan abnormality, circuit board abnormality, backlight abnormality Warning display CAUTION indicator Flashes in amber (every second) 1) Power indicator - Symptom Decreases the brightness to protect the panel from overheating 1) When using in the HDR display, regardless of the input signal, the screen brightness may decrease when the protective function for the LCD panel activates. Keep the temperature of the peripheral environment of the unit around 25 °C (77 °F) to avoid brightness decrease due to the protection function. For the installation environment of the unit, see "On Installation" (page 3). For details on the HDR (High Dynamic Range) display, see "On High Brightness Display" (page 4). About operations using the Sony monitor control unit (the controller) When the optional controller (BKM-17R) is connected, the following operations are possible using the controller buttons. Menu operation buttons Button MENU button ENTER button Operations When the on-screen menu is not displayed, press the button to display the menu. Press again to clear the menu. When the menu is displayed, press the button to reset the value of an item to the previous value. When the menu is displayed, press the button to confirm a menu item or setting value. However, displaying the signal format by pressing and holding the button is not available. Button UP button DOWN button Operations When the menu is displayed, press the button to select a menu item or setting value. Power button Button MONITOR switch Operations Switches the unit status. The unit enters sleep mode if this is pressed when the unit is in operating mode. The Power indicator and STATUS indicator on the front panel of the unit light up in red. Press the button for On mode when the unit is in sleep mode. Rotary encoder/MANUAL buttons Knob CONTRAST knob BRIGHT knob CHROMA knob PHASE knob Operations Adjusts the picture brightness under "Ch. Setting" (page 21) in the "User Preset Setting" menu. Adjusts all the RGB (red/green/blue) together under "User Color Temp." (page 23) in the "User Preset Setting" menu. Adjusts the picture brightness under "Ch. Setting" (page 21) in the "User Preset Setting" menu. Adjusts the B (blue) under "User Color Temp." (page 23) in the "User Preset Setting" menu. Adjusts the color intensity under "Ch. Setting" (page 21) in the "User Preset Setting" menu. Adjusts the G (green) under "User Color Temp." (page 23) in the "User Preset Setting" menu. Adjusts the R (red) under "User Color Temp." (page 23) in the "User Preset Setting" menu. Button CONTRAST MANUAL button BRIGHT MANUAL button CHROMA MANUAL button PHASE MANUAL button Operations Not available on this unit. Not available on this unit. Not available on this unit. Not available on this unit. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55

9
About error/warning signals of the indicator
While the unit is in use, the
(Power) switch
indicator or CAUTION indicator of the front panel
may show error or warning signals.
If an error display appears, refer to Sony qualified
service personnel.
Error display
Warning display
1)
When using in the HDR display, regardless of the input
signal, the screen brightness may decrease when the
protective function for the LCD panel activates. Keep the
temperature of the peripheral environment of the unit
around 25 °C (77 °F) to avoid brightness decrease due to the
protection function. For the installation environment of the
unit, see “On Installation” (page 3).
For details on the HDR (High Dynamic Range) display, see
“On High Brightness Display” (page 4).
About operations using the Sony monitor control
unit (the controller)
When the optional controller (BKM-17R) is
connected, the following operations are possible
using the controller buttons.
Menu operation buttons
Power button
Rotary encoder/MANUAL buttons
CAUTION indicator
Power indicator
Symptom
Flashes in red
(every second)
Power abnormality,
circuit board
abnormality, sensor
abnormality
Flashes in red
(every two
seconds)
Fan abnormality, circuit
board abnormality,
backlight abnormality
CAUTION indicator
Power indicator
Symptom
Flashes in amber
(every second)
1)
Decreases the
brightness to protect
the panel from
overheating
Button
Operations
MENU button
When the on-screen menu is not
displayed, press the button to display
the menu. Press again to clear the
menu.
When the menu is displayed, press the
button to reset the value of an item to
the previous value.
ENTER button
When the menu is displayed, press the
button to confirm a menu item or
setting value.
However, displaying the signal format
by pressing and holding the button is
not available.
UP button
DOWN button
When the menu is displayed, press the
button to select a menu item or setting
value.
Button
Operations
MONITOR
switch
Switches the unit status.
The unit enters sleep mode if this is
pressed when the unit is in operating
mode. The Power indicator and STATUS
indicator on the front panel of the unit
light up in red.
Press the button for On mode when
the unit is in sleep mode.
Knob
Operations
CONTRAST knob
Adjusts the picture brightness under
“Ch. Setting” (page 21) in the “User
Preset Setting” menu.
Adjusts all the RGB (red/green/blue)
together under “User Color Temp.”
(page 23) in the “User Preset Setting”
menu.
BRIGHT knob
Adjusts the picture brightness under
“Ch. Setting” (page 21) in the “User
Preset Setting” menu.
Adjusts the B (blue) under “User Color
Temp.” (page 23) in the “User Preset
Setting” menu.
CHROMA knob
Adjusts the color intensity under “Ch.
Setting” (page 21) in the “User Preset
Setting” menu.
Adjusts the G (green) under “User
Color Temp.” (page 23) in the “User
Preset Setting” menu.
PHASE knob
Adjusts the R (red) under “User Color
Temp.” (page 23) in the “User Preset
Setting” menu.
Button
Operations
CONTRAST MANUAL
button
Not available on this unit.
BRIGHT MANUAL
button
Not available on this unit.
CHROMA MANUAL
button
Not available on this unit.
PHASE MANUAL
button
Not available on this unit.
Button
Operations