Sony RCP-1000 Operation Guide - Page 8

Camera/panel control block, Camera/CCU function ON/OFF buttons - manual

Page 8 highlights

Camera/panel control block a PARA (parallel control) button This is the PARA function button. It allows you to simultaneously control the control panels that are active. However, IRIS and master black are only enabled on control panels on which IRIS/MB is active, and cannot be controlled simultaneously. b CAM PW (camera power) button This button is for supplying power from the CCU to the camera heads. Lighting state Meaning On The power is being supplied. Off The power is disconnected. It is not supplied even if the button is pressed. Slow flashing The power is disconnected. It is supplied when the button is pressed. Fast flashing The camera is starting up. c BARS (color bars signal output) button This button lights when pressed and is for operating the color bar signal generator of the camera to output the corresponding signal. Note When the BARS button is lit, the function of the BARS button takes priority for CCU output. When you select TEST, press the BARS button to turn its light off. d CLOSE (iris close) button This button is for closing the iris of the lens connected to the camera. Pressing it when the auto iris is on changes the iris indication to CLS. Pressing it when the auto iris is off displays the iris value, and the state of that iris value is restored when the close mode is cancelled. e STANDARD button This button is for accessing the standard state of the camera. After the standard state is accessed, you can cancel access by pressing this button again while it is lit. f AWB (auto white balance) button This button is for starting auto white balance adjustment. The button is lit while this function is running and goes out when adjustment is finished. Pressing it again or pressing the START/BREAK button while this function is running stops automatic adjustment. The button flashes to indicate that this function is stopped, and pressing the button again stops the flashing indication. g ABB (auto black balance) button This button is for starting auto black balance adjustment. The button is lit while this function is running and goes out when adjustment is finished. Pressing it again or pressing the START/BREAK button while this function is running stops automatic adjustment. The button flashes to indicate that this function is stopped, and pressing the button again stops the flashing indication. h Camera/CCU function ON/OFF buttons These buttons are for various functions. A function is enabled when its button is lit. A function with an OFF indication is off when the button is lit. Button 5600K CHARACTER Description Electric color temperature correction function CNU character button Turns ON/OFF character output of the CNU and switches to the next page. When this function is ON, each press of the button switches to the next page (holding the button switches to the last page and stops the function in the OFF state). For details on for what kind of image output characters are displayed, refer to the operation manual of the device of the connection destination. 8 Names and Functions of Parts

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

8
Names and Functions of Parts
Camera/panel control block
a
PARA (parallel control) button
This is the PARA function button. It allows you to
simultaneously control the control panels that are active.
However, IRIS and master black are only enabled on control
panels on which IRIS/MB is active, and cannot be controlled
simultaneously.
b
CAM PW (camera power) button
This button is for supplying power from the CCU to the camera
heads.
c
BARS (color bars signal output) button
This button lights when pressed and is for operating the color
bar signal generator of the camera to output the corresponding
signal.
When the BARS button is lit, the function of the BARS button
takes priority for CCU output. When you select TEST, press
the BARS button to turn its light off.
d
CLOSE (iris close) button
This button is for closing the iris of the lens connected to the
camera. Pressing it when the auto iris is on changes the iris
indication to CLS. Pressing it when the auto iris is off displays
the iris value, and the state of that iris value is restored when
the close mode is cancelled.
e
STANDARD button
This button is for accessing the standard state of the camera.
After the standard state is accessed, you can cancel access by
pressing this button again while it is lit.
f
AWB (auto white balance) button
This button is for starting auto white balance adjustment. The
button is lit while this function is running and goes out when
adjustment is finished. Pressing it again or pressing the
START/BREAK button while this function is running stops
automatic adjustment. The button flashes to indicate that this
function is stopped, and pressing the button again stops the
flashing indication.
g
ABB (auto black balance) button
This button is for starting auto black balance adjustment. The
button is lit while this function is running and goes out when
adjustment is finished. Pressing it again or pressing the
START/BREAK button while this function is running stops
automatic adjustment. The button flashes to indicate that this
function is stopped, and pressing the button again stops the
flashing indication.
h
Camera/CCU function ON/OFF buttons
These buttons are for various functions. A function is enabled
when its button is lit. A function with an OFF indication is off
when the button is lit.
Lighting state
Meaning
On
The power is being supplied.
Off
The power is disconnected. It is not supplied even
if the button is pressed.
Slow flashing
The power is disconnected. It is supplied when the
button is pressed.
Fast flashing
The camera is starting up.
Note
Button
Description
5600K
Electric color temperature correction
function
CHARACTER
CNU character button
Turns ON/OFF character output of
the CNU and switches to the next
page. When this function is ON, each
press of the button switches to the
next page (holding the button
switches to the last page and stops
the function in the OFF state). For
details on for what kind of image
output characters are displayed, refer
to the operation manual of the device
of the connection destination.