Sony STR-DG500 Operating Instructions - Page 28

Error codes, To rectify the error, Error code and remedies, Error and warning codes - error 20

Page 28 highlights

The table below shows the display when measurement starts. Measurement for Environment noise level Speaker connection Speaker level Speaker distance Display NOISE.CHK MEASURE and SP DET. appears alternately* MEASURE and GAIN appears alternately* MEASURE and DISTANCE appears alternately* * The corresponding speaker indicator lights up in the display during measurement. When measurement ends, "COMPLETE" appears on the display and the settings are registered. Notes • Auto Calibration cannot detect the sub woofer. Therefore, all sub woofer settings will be maintained. • You cannot select Auto Calibration when headphone is connected. • The measurement process will take a few minutes to complete. Tips • When Auto Calibration starts: - Stand some distance from the speakers and the listening position to avoid measurement failure. This is because test signals are output from the speakers during measurement. - Avoid making noise to get a more accurate measurement. • The Auto Calibration function will be canceled when you do the following during the measurement process: - Press ?/1, input buttons or MUTING. - Change the volume level. - Press AUTO CAL again. Error and warning codes Error codes When an error is detected during Auto Calibration, an error code will appear on the display cyclically after each measurement process as follows: Error code t blank display t (error code t blank display)a) t PUSH t blank display t ENTER a)Appears when there are more than one error code. To rectify the error 1 Record down the error code. 2 Press the control button. 3 Press ?/1 to turn off the receiver. 4 Rectify the error. For details, see "Error code and remedies" below. 5 Turn on the receiver and perform Auto Calibration again (page 27). Error code and remedies Error code Explanation Remedies ERROR 10 The environment Make sure the is too noisy. environment is quiet during Auto Calibration. ERROR 11 The speakers are Place your speakers placed too near further away from the optimizer the optimizer microphone. microphone. ERROR 20 Front speakers Check the front are not detected speaker or only one front connection. speaker is detected. ERROR 21 Only one Check the surround surround speaker speaker is detected. connection. ERROR 23 Surround back speaker is detected but surround speakers are not connected. Be sure to connect the surround speakers. 28GB

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

28
GB
The table below shows the display when
measurement starts.
* The corresponding speaker indicator lights up in
the display during measurement.
When measurement ends, “COMPLETE”
appears on the display and the settings are
registered.
Notes
• Auto Calibration cannot detect the sub woofer.
Therefore, all sub woofer settings will be
maintained.
• You cannot select Auto Calibration when
headphone is connected.
• The measurement process will take a few minutes
to complete.
Tips
• When Auto Calibration starts:
Stand some distance from the speakers and the
listening position to avoid measurement failure.
This is because test signals are output from the
speakers during measurement.
Avoid making noise to get a more accurate
measurement.
• The Auto Calibration function will be canceled
when you do the following during the
measurement process:
– Press
?
/
1
, input buttons or MUTING.
Change the volume level.
Press AUTO CAL again.
Error codes
When an error is detected during Auto
Calibration, an error code will appear on the
display cyclically after each measurement
process as follows:
Error code
t
blank display
t
(error code
t
blank display)
a)
t
PUSH
t
blank display
t
ENTER
a)
Appears when there are more than one error code.
To rectify the error
1
Record down the error code.
2
Press the control button.
3
Press
?
/
1
to turn off the receiver.
4
Rectify the error.
For details, see “Error code and remedies”
below.
5
Turn on the receiver and perform Auto
Calibration again (page 27).
Error code and remedies
Measurement for
Display
Environment noise level
NOISE.CHK
Speaker connection
MEASURE and SP
DET. appears
alternately*
Speaker level
MEASURE and
GAIN appears
alternately*
Speaker distance
MEASURE and
DISTANCE appears
alternately*
Error and warning codes
Error
code
Explanation
Remedies
ERROR 10
The environment
is too noisy.
Make sure the
environment is
quiet during Auto
Calibration.
ERROR 11
The speakers are
placed too near
the optimizer
microphone.
Place your speakers
further away from
the optimizer
microphone.
ERROR 20
Front speakers
are not detected
or only one front
speaker is
detected.
Check the front
speaker
connection.
ERROR 21
Only one
surround speaker
is detected.
Check the surround
speaker
connection.
ERROR 23
Surround back
speaker is
detected but
surround
speakers are not
connected.
Be sure to connect
the surround
speakers.