19 Specifications 19 Specifications 19.1 STIHL RE 100.0 PLUS CONTROL For household use. - Weight with spray attachment and high-pressure hose: approximately 19.8 lbs (9 kg) Electrical - Fuse (characteristic "C" or "D" based on UL 489): 15 A - Mains voltage: 120 V - Frequency: 60 Hz - Rated current: 13 A - Insulation: Class II (Double Insulation) - Approved batteries: AAA batteries (IEC size LR03) - Frequency band: ISM band 2.4 GHz - Maximum RF power transmitted: 13 mW - Signal range: approx. 52 ft (16 m). The signal strength depends on the ambient conditions High-Pressure Pump - Rated Pressure: 1800 psi (12.4 MPa / 124 bar) - Maximum Pressure: 2170 psi (15 MPa / 150 bar) - Minimum water throughput: 1.2 gpm (4.5 l/min) - Maximum water throughput: 1.9 gpm (7.2 l/min) - Maximum suction height from a tank: 1.6 ft. (0.5 m) - Maximum water temperature in pressure mode: 104 °F (40 °C) Water Supply - Minimum length of water hose: 30 ft. (10 m) - Minimum pressure: 14.5 psi (0.1 MPa / 1 bar) - Maximum water inlet pressure: 145 psi (1 MPa / 10 bar) English - Maximum water temperature: 104 °F (40 °C) Pressure-dependent data were measured at an inlet pressure of 0.3 MPa (44 psi). 19.2 Symbols on the Pressure Washer Symbol A V Hz kW t p Q m Explanation Ampere Volt Hertz Kilowatt Temperature Pressure Water throughput Weight Spray gun trigger is locked. Spray Gun trigger is unlocked. Drain the detergent spray set before transport or secure it so that it cannot topple over and cannot move. Certification/listing mark of Intertek. STIHL products must not be disposed of in the household trash, but only in accordance with local, state and federal laws and regulations and as provided in this manual, @ 21. Insulation: Class II (Double Insulation) 0458-004-8621-A 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84

0458-004-8621-A
35
English
19 Specifications
19.1
STIHL RE 100.0 PLUS CONTROL
For household use.
Weight with spray attachment and high-pressure hose:
approximately 19.8 lbs (9 kg)
Electrical
Fuse (characteristic "C" or "D" based on UL 489): 15 A
Mains voltage: 120 V
Frequency: 60 Hz
Rated current: 13 A
Insulation: Class II (Double Insulation)
Approved batteries: AAA batteries (IEC size LR03)
Frequency band: ISM band 2.4 GHz
Maximum RF power transmitted: 13 mW
Signal range: approx. 52 ft (16 m). The signal strength
depends on the ambient conditions
High-Pressure Pump
Rated Pressure: 1800 psi (12.4 MPa / 124 bar)
Maximum Pressure: 2170 psi (15 MPa / 150 bar)
Minimum water throughput: 1.2 gpm (4.5 l/min)
Maximum water throughput: 1.9 gpm (7.2 l/min)
Maximum suction height from a tank: 1.6 ft. (0.5 m)
Maximum water temperature in pressure mode: 104 °F
(40 °C)
Water Supply
Minimum length of water hose: 30 ft. (10 m)
Minimum pressure: 14.5 psi (0.1 MPa / 1 bar)
Maximum water inlet pressure: 145 psi (1 MPa / 10 bar)
Maximum water temperature: 104 °F (40 °C)
Pressure-dependent data were measured at an inlet
pressure of 0.3 MPa (44 psi).
19.2
Symbols on the Pressure Washer
19 Specifications
Symbol
Explanation
A
Ampere
V
Volt
Hz
Hertz
kW
Kilowatt
t
Temperature
p
Pressure
Q
Water throughput
m
Weight
Spray gun trigger is locked.
Spray Gun trigger is unlocked.
Drain the detergent spray set before transport or
secure it so that it cannot topple over and cannot
move.
Certification/listing mark of Intertek.
STIHL products must not be disposed of in the
household trash, but only in accordance with local,
state and federal laws and regulations and as
provided in this manual,
@
21.
Insulation: Class II (Double Insulation)