    INSTALLATION GUIDE Integrated Refrigeration
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 2
    Refrigeration 3 Model Specifications 4 Site Preparation 7 Integrated Installation 12 Service Information 22 Features and specifications are subject to change at any time without notice. Visit subzero.com/specs for the most up-todate information. IMPORTANT NOTE: Throughout this guide, dimensions
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 3
    . Any questions or problems regarding the installation should be directed to your authorized Sub-Zero dealer or Sub-Zero customer care at 800-222-7820. You may also check the contact & support section of our website, subzero.com. Important product information, including the model and serial number
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 4
    ) 341/2" (876) HEIGHT DIMENSIONS ± 1/2" (13) 9 3/4" (248) 4" (102) 24" (610) 45/8" (117) 251/2" (648) 24" (610) 191/2" (495) 45/8" (117) 251/2" (648) DIMENSIONS WILL VARY WITH PANEL THICKNESS MODELS IC-27R AND IC-27FI DIMENSIONS WILL VARY WITH PANEL THICKNESS MODELS 700TR, 700TFI AND 700TCI
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 5
    ) TO TOP OF 3/8" OPENNG (10) 1/2" (13) 131/4" (337) 20 3/8" (518) 101/4" (260) 341/2" (876) HEIGHT DIMENSIONS ± 1/2" (13) 9 3/4" (248) 4" (102) 24" (610) 191/2" (495) 7" (178) 341/2" (876) DIMENSIONS WILL VARY WITH PANEL THICKNESS MODELS 736TR, 736TFI AND 736TCI 5 subzero.com/specs
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 6
    257/8" (657) DIMENSIONS WILL VARY WITH PANEL THICKNESS MODELS 700BR, 700BF(I) AND 700BC(I) Specifications INTEGRATED MODELS Interior Capacity COLUMN MODELS IC-27R IC-27FI 27" (686) TALL MODELS 700TR 700TFI 700TCI 36" (914) TALL MODELS 736TR 736TFI 736TCI 27" (686) DRAWER MODELS 700BR 700BF(I) 700BC
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 7
    Dimensions INTEGRATED MODELS 25" (635) OPENING DEPTH TOP VIEW 7 subzero.com/specs IMPORTANT NOTE: The depth of each integrated model VIEW Opening Dimensions IC-27R and IC-27FI 700TR, 700TFI, 700TCI 736TR, 736TFI, 736TCI 700BR, 700BF(I), 700BC(I) FRONT VIEW A 27" (686) 27" (686) 36" (914) 27" (686
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 8
    Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required. A ground fault 330) 41/2" (114) 1/4" FLOOR (6) FRONT VIEW 27" (686) models. 21/2" (64) 171/2" (445) 1/4" FLOOR (6) FRONT VIEW 41/2" (114) 36" (
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 9
    compressor tray. The tray must be slid forward for service. The water supply line should be connected to the house supply with an easily accessible shut-off valve between the supply and the unit. Do not use self-piercing valves. A saddle valve kit is available from your authorized Sub-Zero dealer
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 10
    the front of the unit (without panels) to the back of the anti-tip bracket. IMPORTANT NOTE: In some installations the subflooring or finished floor may tight. Refer to the illustration below. Anti-Tip Bracket Placement 27" (686) Models 36" (914) Models A 131/2" (343) 18" (457) Make sure there
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 11
    Site Preparation 11 subzero.com/specs Anti-Tip Bracket Installation INSTALL CONCRETE WEDGE ANCHORS: 1) Drill a 3/8" (10) until you are ready for installation of the panels. Remove the decorative top and side moldings and the kickplate/grille. IMPORTANT NOTE: For drawer models, the top drawer has
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 12
    Installation 12 Position the Unit Plug the power cord into the grounded electrical outlet. With power applied to the appliance, check for lighting and cooling. Press the UNIT ON/OFF key pad on the control panel (POWER for column models floor. FREEZER COLDER WARMER COLDER WARMER REFRIGERATOR ON/
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 13
    Integrated Installation 13 subzero.com/specs Molding Installation Install the decorative white molding strips to the top and sides of the integrated unit for a finished look. The top molding strip, used on column and tall models, must be installed before the side molding can be attached. The top
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 14
    . For local dealer information, visit the find a showroom section of our website, subzero.com. Check panel dimensions before proceeding. Additional panel information can be found in the Sub-Zero design guide and on our website, subzero.com. IMPORTANT NOTE: A portion of the backside of the decorative
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 15
    Integrated Installation 15 subzero.com/specs Panel Considerations TYPICAL PANEL DIMENSIONS 26 3/4" (679) PANEL WIDTH 26 3/4" (679) PANEL WIDTH 1/8" (3) 1/8" (3) 1/8" (3) 35 3/4" (908) PANEL WIDTH 767/8" (1953) 45 3/8" (1153) 807/8" (2054) 45 3/8" (1153) 79 7/8" (2029) 4" (102) 27" (686)
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 16
    Integrated Installation 16 Panel Considerations DOOR PANEL HEIGHT The height of the door panel can extend beyond the typical panel height, provided you do not exceed the panel weight limit. A minimum finished height of 80" (2032) is required for 27" (686) and 36" (914) tall models. For the 27" (
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 17
    Integrated Installation 17 subzero.com/specs Panel Installation DOOR PANEL INSTALLATION Remove the two pieces of mounting hardware attached to the front of the door and set aside. Place the door panel lying face down on a protected surface to ensure that the front is not scratched or damaged.
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 18
    46) 23 7/8" (606) FOR 27" UNITS 32 7/8" (835) FOR 36" UNITS 17/16" (37) RH DOOR SWING BACK OF PANEL LH DOOR SWING BACK OF PANEL RH DOOR SWING BACK OF PANEL LH DOOR SWING BACK OF PANEL 7 3/16"* (183) 811/16"* (221) *Dimensions are based on a 4" (102) toe kick. COLUMN MODELS 55/16" (135) 115
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 19
    Integrated Installation 19 subzero.com/specs Panel Installation DRAWER PANEL INSTALLATION Remove the mounting hardware provided and set aside. As with the door panel, you should work on the back side of each drawer panel to protect the front surface. Position the top edge of the template flush
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 20
    in a dual installation. Panel width dimensions will vary slightly from single installations. A dual installation kit is required for installations with 2" (51) or less space between units. Dual installation kits are available through your authorized Sub-Zero dealer. IMPORTANT NOTE: If a 27" (686
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 21
    package? Have any installation or service problems been noted on the product registration card? Has the registration card been mailed in? Have stainless steel panels been inspected for any imperfections? This is to be done by the authorized Sub-Zero dealer or installer with the customer, upon
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 22
    unit by calling Sub-Zero factory certified service. For the name and number of Sub-Zero factory certified service nearest you, check the contact & support section of our website, subzero.com or call Sub-Zero customer care at 800-222-7820. When calling for service, you will need the model and serial
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 23
    part without the express written permission of Sub-Zero, Inc. ©Sub-Zero, Inc. all rights reserved. Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero, Sub-Zero & Design, Dual Refrigeration
  • Sub-Zero 700BCI | Integrated Installation Guide - Page 24
    SUB-ZERO, INC. P. O. BOX 44848 MADISON, WI 53744 SUBZERO.COM 800.222.7820 7023602 REV-A 8/2011
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

INSTALLATION GUIDE
Integrated Refrigeration