Sub-Zero 700BCI Integrated Installation Guide - Page 8
Site Preparation, Electrical Requirements
View all Sub-Zero 700BCI manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 8 highlights
Site Preparation 8 Electrical Requirements The electrical supply should be located within the shaded area shown in the illustrations below. Follow the National Electrical Code and local codes and ordinances when installing the receptacle. A separate circuit, servicing only this appliance is required. A ground fault circuit interrupter (GFCI) is not recommended and may cause interruption of operation. IMPORTANT NOTE: It is critical that the electrical outlet be located within the shaded area shown so it does not interfere with installation of the anti-tip bracket. It must be flush with the back wall and positioned with the grounding prong to the right of the thinner blades. Electrical Requirements Power Supply Circuit Breaker Receptacle 115 V AC, 60 Hz 15 amp 3-prong grounding-type The outlet must be checked by a qualified electrician to be sure that it is wired with the correct polarity. Verify that the outlet is properly grounded. Do not use an extension cord or two-prong adapter. Do not remove the power supply cord ground prong. LEFT SIDE OF OPENING LEFT SIDE OF OPENING 21/2" (64) 13" (330) 41/2" (114) 1/4" FLOOR (6) FRONT VIEW 27" (686) models. 21/2" (64) 171/2" (445) 1/4" FLOOR (6) FRONT VIEW 41/2" (114) 36" (914) models.