TASCAM CG-1800 Release Notes - Page 1

TASCAM CG-1800 Manual

Page 1 highlights

CG-2000/CG-1800/CG-1000 Release Notes Updates Always use the most recent firmware version for this unit. For information about the latest firmware, visit the TEAC Global Site (http://teac-global.com/). New functions V1.04 addition o A SCREEN SAVERitem has been added to the Menu Screen UTILITY 1page. This function prevents the occurrence of afterimages on the display during use for long periods of time. NOTE A screen saver function has been added. For details, see "New functions in firmware version 1.04" in the CG-2000/CG-1800/ CG-1000 addendum. Maintenance items V1.08 improvement o Fixed a bug that the end detection display function of video output may be displayed incorrectly. V1.07 improvements o Unlocked judgments are now controlled for reference inputs with large amounts of jitter. This change only affects error display. It has no effect on operation itself. o Video output chasing judgments are now controlled for reference inputs with large amounts of jitter. This change only affects error display. It has no effect on operation itself. V1.06 improvement o Sometimes it would take some time to lock with an external reference signal immediately after starting up. This has been improved (CG-2000/CG-1800 only). V1.05 improvements o If the reference clock setting was changed when it was switching, sometimes locking would not complete. The performance of this function has been improved. o When RED. SEQ.(redundant sequencing) was set to ONE WAY, if both the primary and secondary references were lost, HOLD OVER operation would continue after recovery, but sometimes using PRESET RECALL for primary recovery would not succeed in one operation. The performance of this function has been improved. V1.04 improvements o Sometimes relocking would not occur immediately after starting up during the period when the OCXO was unstable. The performance of this function has been improved. o The activation of the redundant sequencing (RED. SEQ.) setting has been changed from immediately after starting up to after the OCXO stabilizes. o Until the OCXO stabilizes, the unit will operate with preference given to the primary source (PREF.PRI). As a result, the issue of reference clock loss and holdover that sometimes occurred during the period when the OCXO was unstable immediately after starting up (when the INTERNAL SIGNAL LED was blinking) has been resolved. V1.03 improvement o If the reference clock was set to WORD, but the quality of the word reference signal was poor, the LOCK (green) and INFO (blue) indicators would not light after locking sometimes. This has been improved so that they light properly. V1.02 improvements o Even if the unit is turned on when no reference clock is being input, it can now generate synchronized video clock and audio clock (CG-2000/CG-1800 only). o When the AUTO RATEitem on the VIDEO CLOCKscreen is set to ON, the unit will no longer automatically set formats that it does not support (720P/30fps, etc.) (CG-2000/CG-1800 only). V1.01 improvements o If the unit is turned on while the reference clock is set to INTERNAL, WORDor AES, and then redundancy is set to use video and audio reference (WORDor AES), the word clock output signal will stay stable even when switching the reference clock from audio reference to video reference as a result of the redundancy function (CG-2000 only). o If the unit is turned on while the reference clock is set to VIDEObut no video reference signal is being input, when a video reference signal is input later, the amount of time required to lock to it has been reduced (CG-2000 only). o When redundancy is set for video and word reference (WORD or AES), the amount of time required to lock to the video reference signal has been reduced when switching the reference clock from word reference to video reference as a result of the redundancy function (CG-2000 only). o A spelling error has been corrected in the PUSH CANCEL TO CLEARmessage that appears at the bottom of the ERROR INFORMATIONscreen (CANCLE> CANCEL). D01243620E 0321,MA-2887B TASCAM CG-2000/CG-1800/CG-1000 1

  • 1
  • 2

TASCAM CG-2000/CG-1800/CG-1000
1
CG-2000/CG-1800/CG-1000
Release Notes
Updates
Always use the most recent firmware version for this unit. For
information about the latest firmware, visit the TEAC Global Site
(http://teac-global.com/).
New functions
V1.04 addition
o
A
SCREEN SAVER
item has been added to the Menu
Screen
UTILITY 1
page. This function prevents the
occurrence of afterimages on the display during use for long
periods of time.
NOTE
A screen saver function has been added. For details, see “New
functions in firmware version 1.04” in the CG-2000/CG-1800/
CG-1000 addendum.
Maintenance items
V1.08 improvement
o
Fixed a bug that the end detection display function of video
output may be displayed incorrectly.
V1.07 improvements
o
Unlocked judgments are now controlled for reference inputs
with large amounts of jitter. This change only affects error
display. It has no effect on operation itself.
o
Video output chasing judgments are now controlled for
reference inputs with large amounts of jitter. This change
only affects error display. It has no effect on operation itself.
V1.06 improvement
o
Sometimes it would take some time to lock with an external
reference signal immediately after starting up. This has been
improved (CG-2000/CG-1800 only).
V1.05 improvements
o
If the reference clock setting was changed when it was
switching, sometimes locking would not complete. The
performance of this function has been improved.
o
When
RED. SEQ.
(redundant sequencing) was set to
ONE
WAY
, if both the primary and secondary references were
lost, HOLD OVER operation would continue after recovery,
but sometimes using PRESET RECALL for primary recovery
would not succeed in one operation. The performance of this
function has been improved.
V1.04 improvements
o
Sometimes relocking would not occur immediately after
starting up during the period when the OCXO was unstable.
The performance of this function has been improved.
o
The activation of the redundant sequencing (
RED. SEQ.
)
setting has been changed from immediately after starting up
to after the OCXO stabilizes.
o
Until the OCXO stabilizes, the unit will operate with
preference given to the primary source (PREF.PRI). As a result,
the issue of reference clock loss and holdover that sometimes
occurred during the period when the OCXO was unstable
immediately after starting up (when the
INTERNAL SIGNAL
LED
was blinking) has been resolved.
V1.03 improvement
o
If the reference clock was set to WORD, but the quality of the
word reference signal was poor, the
LOCK
(green) and
INFO
(blue) indicators would not light after locking sometimes.
This has been improved so that they light properly.
V1.02 improvements
o
Even if the unit is turned on when no reference clock is being
input, it can now generate synchronized video clock and
audio clock (CG-2000/CG-1800 only).
o
When the
AUTORATE
item on the
VIDEOCLOCK
screen
is set to
ON
, the unit will no longer automatically set formats
that it does not support (720P/30fps, etc.) (CG-2000/CG-1800
only).
V1.01 improvements
o
If the unit is turned on while the reference clock is set to
INTERNAL
,
WORD
or
AES
, and then redundancy is set to
use video and audio reference (
WORD
or
AES
), the word
clock output signal will stay stable even when switching the
reference clock from audio reference to video reference as a
result of the redundancy function (CG-2000 only).
o
If the unit is turned on while the reference clock is set to
VIDEO
but no video reference signal is being input, when
a video reference signal is input later, the amount of time
required to lock to it has been reduced (CG-2000 only).
o
When redundancy is set for video and word reference (
WORD
or
AES
), the amount of time required to lock to the video
reference signal has been reduced when switching the
reference clock from word reference to video reference as a
result of the redundancy function (CG-2000 only).
o
A spelling error has been corrected in the
PUSHCANCELTOCLEAR
message that appears at the
bottom of the
ERRORINFORMATION
screen (
CANCLE
>
CANCEL
).
D01243620E
0321,MA-2887B