TCL W5W3M-3 User Manual - Page 6

Installation Safety Principles

Page 6 highlights

Category LFL (kg/m3) h 0 (m) 0,6 1 R32 0,306 1,8 2,2 Table GG.1 - Maximum charge (kg) Floor area (m2) 4 7 10 15 20 0,68 0,9 1,08 0,32 1,53 1,14 1,51 1,8 2,2 2,54 2,05 2,71 3,24 3,97 4,58 2,5 3,31 3,96 4,85 5,6 30 1,87 3,12 5,61 6,86 Table GG.2 - Minimum room area (m2) Charge amount (M) (kg) Category LFL (kg/m3) h 0 (m) Minimum room area (m2) 1,224 kg 1,836 kg 2,448 kg 3,672 kg 4,896 kg 6,12 kg 0,6 29 51 116 206 321 1 R32 0,306 1,8 10 19 42 74 116 3 6 13 23 36 2,2 2 4 0 15 24 Installation Safety Principles 1. Site Safety Open Flames Prohibited Ventilation Necessary 50 2,41 4,02 7,254 8,85 7,956 kg 543 196 60 40 2. Operation Safety Mind Static Electricity Open Flames Prohibited Must wear protective clothing and anti-static gloves Don`t use mobile phone 3. Installation Safety • Refrigerant Leak Detector • Appropriate Installation Location The left picture is the schematic diagram of a refrigerant leak detector. Please note that: 1. The installation site should be in a well-ventilated area. 2. The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding, smoking, drying oven or any other heat source higher than 548°C which easily produces open fire. 3. When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-static clothing and/or gloves. 4. Installation or maintenance location should not be surrounded by obstacles or close to any heat source, flammable, and/or explosive areas or objects. 5. If the product suers refrigerant leak during the installation, all personnel should go out till the refrigerant leaks completely for 15 minutes. If the product is damaged, a professional must carry such damages product back to the maintenance station. It is prohibited to weld the refrigerant pipe or conduct other operations on the contaminated site. 6. The air conditioner unit needs to sit on a flat even surface. 7. It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables directly under the lines on two sides of the indoor unit. 8. Any ventilation openings of unit should be free from obstructions. 6

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

6
Table GG.1 - Maximum charge (kg)
Category
LFL
(kg/m
3
)
h
0
(m)
Floor area (m
2
)
4
7
10
15
20
30
50
R32
0,306
0,6
0,68
0,9
1,08
0,32
1,53
1,87
2,41
1
1,14
1,51
1,8
2,2
2,54
3,12
4,02
1,8
2,05
2,71
3,24
3,97
4,58
5,61
7,254
2,2
2,5
3,31
3,96
4,85
5,6
6,86
8,85
Table GG.2 - Minimum room area (m2)
Category
LFL
(kg/m
3
)
h 0
(m)
Charge amount (M) (kg)
Minimum room area (m2)
1,224 kg
1,836 kg
2,448 kg
3,672 kg
4,896 kg
6,12 kg
7,956 kg
R32
0,306
0,6
29
51
116
206
321
543
1
10
19
42
74
116
196
1,8
3
6
13
23
36
60
2,2
2
4
0
15
24
40
Installation Safety Principles
1. Site Safety
Open Flames Prohibited
Ventilation Necessary
2. Operation Safety
Open Flames Prohibited
3. Installation Safety
• Refrigerant Leak Detector
• Appropriate Installation Location
The left picture is the schematic diagram of a refrigerant
leak detector.
Please note that:
1.
The installation site should be in a well-ventilated area.
2.
The sites for installing and maintaining an air conditioner using Refrigerant R32 should be free from open fire or welding, smoking, drying
oven or any other heat source higher than 548
°C
which easily produces open fire.
3.
When installing an air conditioner, it is necessary to take appropriate anti-static measures such as wear anti-static clothing and/or gloves.
4.
Installation or maintenance location should not be surrounded by obstacles or close to any heat source, flammable, and/or explosive
areas or objects.
5.
If the product suers refrigerant leak during the installation, all personnel should go out till the refrigerant leaks completely for 15 minutes.
If the product is damaged, a professional must carry such damages product back to the maintenance station. It is prohibited to weld the
refrigerant pipe or conduct other operations on the contaminated site.
6.
The air conditioner unit needs to sit on a flat even surface.
7.
It is necessary to avoid the places where there are other electrical products, power switch plugs and sockets, kitchen cabinet, bed, sofa
and other valuables directly under the lines on two sides of the indoor unit.
8.
Any ventilation openings of unit should be free from obstructions.
Mind Static Electricity
Must wear protective clothing and
anti-static gloves
Don`t use mobile phone