the corresponding PoE time-range configuration, please use no power time-range command. The PoE time-range determines the power supply time of the switch. You can specify a PoE time-range for each PoE port individually. Syntax power time-range name no power time-range name Parameter name -- The PoE time-range name, ranging from 1 to 16 characters. Command Mode Global Configuration Mode Example Create a PoE time-range named "tRange1" for the switch: T1600G-52PS(config)# power time-range tRange1 25.4 absolute Description The absolute command is used to create an absolute mode time-range for the Time-range of the switch. The Time-range takes affect only when both Absolute Time and Periodic Time are in effect. Repeat this command to create multiple absolute time-ranges. Up to 7 absolute time-ranges can be created in one Time-range, and their union is the Absolute Time-range. If no absolute time range is configured, the absolute time range takes effect from January 1, 2000 00:00 to December 31, 2099 24:00. To delete the corresponding absolute time-range, please use no absolute command. Syntax absolute from start-date to end-date no absolute [ index ] Parameter start-date -- The start date in Absolute Mode, in the format of MM/DD/YYYY-HH:MM. end-date -- The end date in Absolute Mode, in the format of MM/DD/YYYY-HH:MM. 170