TRENDnet TPL-308E Quick Installation Guide - Page 5

Ethernet Port, Sync/Reset Button, Power Prong, Diagnostic LEDs, Button, Action, Function, Reset, Color - tpl 308e2k 200mbps powerline

Page 5 highlights

TRENDnet User's Guide • Ethernet Port - Connect an Ethernet cable (also called network cable) from your Powerline adapter Ethernet port and to your computer or network device. • Sync/Reset Button - Changes the default encryption key or resets the unit to factory defaults. See table below for function. Button Action Sync / Reset (see the section Using the Sync Button for instructions) Sync Push/hold for 3 seconds, then release Reset Push/Hold for 20 seconds, then release Function Initiate Sync/Connection and generate random network name/key (PWR LED will start blinking). Note: The secondary or additional Powerline adapter's Sync button must also be pushed within 2 minutes (120 sec) of pushing the Sync button on the first adapter in order to establish connectivity. Reset device to factory defaults (All LEDs will turn off and turn back on). Note: Will reset to the factory default private network name "HomePlug AV". • Power Prong - Plugs into an available power outlet. • Diagnostic LEDs - Indicates the device status and connectivity. Note: Powerline (PL) LED color indicates the strength and quality of the Powerline connection through the electrical system. © Copyright 2012 TRENDnet. All Rights Reserved. TPL-308E / TPL-308E2K LED PWR (Power) Color Green N/A Green PL (Powerline) Amber Red N/A ETH (Ethernet Green Connection) N/A Sequence Solid Off Solid Blinking Solid Blinking Solid Blinking Off Solid Blinking Off Definition Device powered on Device powered off Powerline connected (Connection quality is Best) Syncing or Powerline data transmitting/receiving (Connection quality is Best) Powerline connected (Connection quality is Better) Powerline data transmitting/receiving (Connection quality is Better) Powerline connected (Connection quality is Good) Powerline data transmitting/receiving (Connection quality is Good) Powerline is not synced or connected 10/20 Mbps , 100/200Mbps (Half/Full Duplex) connected 10/20 Mbps , 100/200Mbps (Half/Full Duplex) data transmitting/receiving Port disconnected/no Ethernet link Note: The following factors may affect the Powerline network's connection quality: • Noise - Generated by appliances which use your electrical system (e.g. Microwaves, ovens, blow dryer, iron, dishwasher, etc.). The quality of your household electrical wiring may also cause additional noise on your electrical system. • Distance - Long lengths of electrical wiring through your electrical system between connected Powerline adapters. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

© Copyright 2012 TRENDnet. All Rights Reserved.
TRENDnet User’s Guide
TPL-308E / TPL-308E2K
3
Ethernet Port -
Connect an Ethernet cable (also called network cable) from
your Powerline adapter Ethernet port and to your computer or network device.
Sync/Reset Button –
Changes the default encryption key or resets the unit to
factory defaults. See table below for function.
Power Prong
– Plugs into an available power outlet.
Diagnostic LEDs –
Indicates the device status and connectivity.
Note:
Powerline (PL) LED color indicates the strength and quality of the Powerline
connection through the electrical system.
Note:
The following factors may affect the Powerline network’s connection quality:
Noise
– Generated by appliances which use your electrical system (e.g.
Microwaves, ovens, blow dryer, iron, dishwasher, etc.). The quality of your
household electrical wiring may also cause additional noise on your electrical
system.
Distance
– Long lengths of electrical wiring through your electrical system
between connected Powerline adapters.
Button
Action
Function
Sync /
Reset
(see the
section
Using the
Sync Button
for
instructions)
Sync
Push/hold for 3
seconds,
then release
Initiate Sync/Connection and generate random
network name/key (PWR LED will start blinking).
Note:
The secondary or additional Powerline
adapter’s Sync button must also be pushed within 2
minutes (120 sec) of pushing the Sync button on the
first adapter in order to establish connectivity.
Reset
Push/Hold for 20
seconds,
then release
Reset device to factory defaults (All LEDs will turn off
and turn back on).
Note: Will reset to the factory default private
network name “HomePlug AV”.
LED
Color
Sequence
Definition
PWR
(Power)
Green
Solid
Device powered on
N/A
Off
Device powered off
PL
(Powerline)
Green
Solid
Powerline connected (Connection quality is
Best)
Blinking
Syncing or Powerline data
transmitting/receiving (Connection quality is
Best)
Amber
Solid
Powerline connected (Connection quality is
Better)
Blinking
Powerline data transmitting/receiving
(Connection quality is Better)
Red
Solid
Powerline connected (Connection quality is
Good)
Blinking
Powerline data transmitting/receiving
(Connection quality is Good)
N/A
Off
Powerline is not synced or connected
ETH
(Ethernet
Connection)
Green
Solid
10/20 Mbps , 100/200Mbps
(Half/Full Duplex) connected
Blinking
10/20 Mbps , 100/200Mbps
(Half/Full Duplex) data transmitting/receiving
N/A
Off
Port disconnected/no Ethernet link