Thermador KBUDT4865E Design Guide - Side-by-Side Refrigeration - Page 4

Refrigeration - Side-by-side, Side-by-side - - 48 professional series

Page 4 highlights

REFRIGERATION - SIDE-BY-SIDE SIDE-BY-SIDE FEATURES & BENEFITS MODEL OPTIONS Select from the 42-inch and 48-inch side-by-side refrigerator, with a full-filtered internal ice maker or external ice and water dispenser. Masterpiece® or Professional Handles are available to match our built-in or Professional Series product lines, or choose our custom panel models to integrate beautifully with your cabinetry. INSTALLATION CONSIDERATIONS The information in this design guide provides key features, product dimensions, cutouts and installation specifications. Before installing a Thermador Sideby-Side, be sure to verify the cabinet dimensions and electrical connections. Also, always consult with the installation manual packed with the product for complete details before installing. The refrigerator can be recessed in an opening between cabinets or installed at the end of a cabinet run using a side panel to enclose the refrigerator. CUSTOM PANELS The custom panel series features factory-installed, traditional style trim to provide a "framed" look. This series requires the installation of custom panels that are not included. You will need to create the panels yourself or consult a qualified cabinetmaker or carpenter. See dimension drawings on the following pages for panel specifications. On the custom panel series, you can create a "frameless" look using full-overlay custom panels. You will need to order a Trimless Trim Kit (TRIMKITSXS). This accessory kit contains parts to replace the factory trim. Full-overlay custom panels and handles are required but not included in the accessory kit. Create the panels according to the specifications in the "Full-Overlay Custom Panels" section. You can order a set of Thermador's handles or select handles from another source. For door clearances, see "Handle and Door Clearances for Custom Panel Series." SIDE PANELS Custom side panels may be needed when not enough space is available to have cabinets on both sides of the refrigerator or when the refrigerator is placed at the end of a cabinet run. For the stainless steel models, you may choose an Inset, Flush, or Recessed Inset panel installation. For the custom panel series, you may choose an Inset or Recessed Inset panel installation. ELECTRICAL SPECIFICATIONS Before you move your refrigerator into its final location, it is important to make sure you have the proper electrical connection. RECOMMENDED GROUNDING METHOD A 115 Volt, 60 Hz., AC only, 15- or 20-Amp fused, grounded electrical supply is required. It is recommended that a separate circuit serving only your refrigerator be provided. Use an outlet that cannot be turned off by a switch. Do not use an extension cord. Important: If this product is connected to a GFCI (Ground Fault Circuit Interrupter) protected outlet, nuisance tripping of the power supply may occur, resulting in loss of cooling. Food quality and flavor may be affected. If nuisance tripping has occurred, and if the condition of the food appears poor, dispose of it. ELECTRICAL LOCATION Be sure your appliance is properly installed and grounded by a qualified technician. Installation, electrical connections and grounding must comply with all applicable local codes. 4" (10.2 cm) A grounded 3 prong electrical outlet should be placed within 4" (10.2 cm) of the right side cabinets or end panel. The water shutoff should be located in the base cabinet on either side of the refrigerator or some other easily accessible area. If the water shutoff valve is not in the cabinets, the plumbing for the water line can come through the floor or the back wall. WATER LOCATION All installations must meet local plumbing code requirements. The water shutoff should be located in the base cabinet on either side of the refrigerator or some other easily accessible area. The right-hand side is recommended. The access hole through the cabinet must be within 1/2" (12.7 mm) of the rear wall. Note: If the water shut off valve is in the back wall behind the refrigerator, it must be at an angle so that the tube is not kinked when the refrigerator is pushed into its final position. If the water shutoff valve is not in the cabinets, the plumbing for the water line can come through the floor. A 1/2" (12.7 mm) hole for plumbing should be drilled at least 6" (15.2 cm) from the right or left hand side cabinet or panel. On the floor, the hole should be no more than 1" (2.54 cm) away from the back wall. If additional tubing is needed, use copper tubing and check for leaks. Install the copper tubing only in areas where the household temperatures will remain above freezing. Do not use a piercing-type or 3/16" (4.76 mm) saddle valve which reduces water flow and clogs more easily. WARRANTY Limited two-year warranty-for two years from date of original purchase, we will provide, free of charge, parts and service labor in your home to repair or replace any part of the refrigerator that fails because of a manufacturing defect. Limited warranty on sealed refrigeration system**; parts and labor (3rd-6th year) Note: Your refrigerator dealer has a kit available with a 1/4" (6.35 mm) saddle-type shutoff valve, a union, and copper tubing. Before purchasing, make sure a saddle-type valve complies with your local plumbing codes. 6" (15.2 cm) Limited warranty on sealed refrigeration system; parts only (7th-12th year) 6" (15.2 cm) 1" (2.54 cm) 24" (60.96 cm) min. 6" (15.2 cm) See page 294 for additional warranty details. 1.800.735.4328 | THERMADOR.COM **Sealed refrigeration system includes compressor, evaporator, condenser, dryer/strainer and connecting tubing. 263

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

263
24"
(60.96 cm) min.
1"
(2.54 cm)
6"
(15.2 cm)
6"
(15.2 cm)
6"
(15.2 cm)
1.800.735.4328
|
THERMADOR.COM
REFRIGERATION — SIDE-BY-SIDE
SIDE-BY-SIDE
FEATURES & BENEFITS
ELECTRICAL SPECIFICATIONS
Before you move your refrigerator into its final location, it is important to
make sure you have the proper electrical connection.
RECOMMENDED GROUNDING METHOD
A 115 Volt, 60 Hz., AC only, 15- or 20-Amp fused, grounded electrical supply
is required. It is recommended that a separate circuit serving only your
refrigerator be provided. Use an outlet that cannot be turned off by a switch.
Do not use an extension cord.
Important:
If this product is connected to a GFCI (Ground Fault Circuit
Interrupter) protected outlet, nuisance tripping of the power supply may
occur, resulting in loss of cooling. Food quality and flavor may be affected.
If nuisance tripping has occurred, and if the condition of the food appears
poor, dispose of it.
ELECTRICAL LOCATION
Be sure your appliance is properly installed and grounded
by a qualified technician. Installation, electrical connections
and grounding must comply with all applicable local codes.
A grounded 3 prong electrical outlet should be placed within
4" (10.2 cm) of the right side cabinets or end panel. The water
shutoff should be located in the base cabinet on either side of the refrigerator
or some other easily accessible area. If the water shutoff valve is not in the
cabinets, the plumbing for the water line can come through the floor or the
back wall.
WATER LOCATION
All installations must meet local plumbing code requirements.
The water shutoff should be located in the base cabinet on either side of
the refrigerator or some other easily accessible area. The right-hand side is
recommended. The access hole through the cabinet must be within
1
/
2
"
(12.7 mm) of the rear wall.
Note:
If the water shut off valve is in the back wall behind the refrigerator,
it must be at an angle so that the tube is not kinked when the refrigerator is
pushed into its final position.
If the water shutoff valve is not in the cabinets, the plumbing for the water line
can come through the floor. A
1
/
2
" (12.7 mm) hole for plumbing should be
drilled at least 6" (15.2 cm) from the right or left hand side cabinet or panel.
On the floor, the hole should be no more than 1" (2.54 cm) away from the
back wall.
If additional tubing is needed, use copper tubing and check for leaks. Install
the copper tubing only in areas where the household temperatures will remain
above freezing.
Do not use a piercing-type or
3
/
16
" (4.76 mm) saddle valve which reduces
water flow and clogs more easily.
Note:
Your refrigerator dealer has a kit available with a
1
/
4
" (6.35 mm)
saddle-type shutoff valve, a union, and copper tubing. Before purchasing,
make sure a saddle-type valve complies with your local plumbing codes.
MODEL OPTIONS
Select from the 42-inch and 48-inch side-by-side
refrigerator, with a full-filtered internal ice maker or
external ice and water dispenser. Masterpiece
®
or
Professional Handles are available to match our built-in or
Professional Series product lines, or choose our custom
panel models to integrate beautifully with your cabinetry.
INSTALLATION CONSIDERATIONS
The information in this design guide provides key
features, product dimensions, cutouts and installation
specifications.
Before installing a Thermador Side-
by-Side, be sure to verify the cabinet dimensions and
electrical connections. Also, always consult with the
installation manual packed with the product for complete
details before installing.
The refrigerator can be recessed in an opening between
cabinets or installed at the end of a cabinet run using a
side panel to enclose the refrigerator.
CUSTOM PANELS
The custom panel series features factory-installed,
traditional style trim to provide a “framed” look. This
series requires the installation of custom panels that are
not included. You will need to create the panels yourself
or consult a qualified cabinetmaker or carpenter. See
dimension drawings on the following pages for panel
specifications.
On the custom panel series, you can create a “frameless”
look using full-overlay custom panels. You will need to
order a Trimless Trim Kit (TRIMKITSXS). This accessory
kit contains parts to replace the factory trim. Full-overlay
custom panels and handles are required but not included
in the accessory kit. Create the panels according to the
specifications in the “Full-Overlay Custom Panels” section.
You can order a set of Thermador’s handles or select
handles from another source. For door clearances, see
“Handle and Door Clearances for Custom Panel Series.”
SIDE PANELS
Custom side panels may be needed when not enough
space is available to have cabinets on both sides of the
refrigerator or when the refrigerator is placed at the
end of a cabinet run. For the stainless steel models, you
may choose an Inset, Flush, or Recessed Inset panel
installation. For the custom panel series, you may choose
an Inset or Recessed Inset panel installation.
WARRANTY
Limited two-year warranty—for two years from date of
original purchase, we will provide, free of charge, parts
and service labor in your home to repair or replace
any part of the refrigerator that fails because of a
manufacturing defect.
Limited warranty on sealed refrigeration system**; parts
and labor (3rd–6th year)
Limited warranty on sealed refrigeration system; parts only
(7th–12th year)
See page 294 for additional warranty details.
4"
(10.2 cm)
**Sealed refrigeration system includes compressor,
evaporator, condenser, dryer/strainer and
connecting tubing.