Thermador PCG486NL Design Guide - Page 12

Built-in Ovens, Professional Rangetops

Page 12 highlights

INSTALLATION OPTIONS To ensure professional results, the cabinet and countertop openings should be prepared by a qualified cabinet worker. The rangetop can be installed in various positions with the front either flush or projecting, depending on the countertop's depth. The rangetop is designed to hang from the countertop by its side flanges. The countertop however, must be strong enough to support the rangetop. It may be necessary to add a supporting cleat along each side or a 2" x 4" corner brace. Another alternative would be to construct a deck to set the rangetop on. Consult with the installation manual packed with the product for complete details before installing. ABOVE A WARMING DRAWER Thermador Professional® Rangetops may be installed above a Thermador Warming Drawer to create a convenient cooking center. A minimum 2 3/4" clearance is required between the bottom of the rangetop and the top of the warming drawer. Refer to the warming drawer section for additional specifications. BACKGUARDS When using the Flush Island Trim, Thermador recommends a minimum 12" (305 mm) rear clearance to a combustible surface (see Figure 1, Cabinet Clearances). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certified by CSA. Clearances of less than 12" (305 mm) must be approved by the local codes and / or by the local authority having jurisdiction. NATURAL GAS OR LP Thermador Professional® Rangetops are shipped by the factory to operate on natural gas. They must be converted for use with propane. Verify the type of gas being used at the installation site matches the type of gas used by the appliance. If the location / job site requires conversion from natural gas to propane (LP), order PALPKITHC. Field conversion must be done by qualified service personnel only. Please refer to the LP Conversion Instructions packed with product for further information. IMPORTANT We strongly recommend that a Thermador Professional Wall or Island Hood or Custom Insert be installed with all Thermador Professional® Rangetops. Downdraft ventilation should not be used. Do not install a microwave-hood combination above the rangetop, as these types of units do not provide the proper ventilation and are not suitable for use with Thermador Professional® Rangetops. Refer to the ventilation section or www.Thermador.com for a complete selection of Professional ventilation options, blowers, and accessories. 1.800.735.4328 | THERMADOR.COM PROFESSIONAL RANGETOPS 48-INCH PCG486GD 48-INCH RANGETOP AND CUTOUT DIMENSIONS as de ned in the "National Fuel Gas Code" (ANSI Z223.1, Current Edition). Clearances from non-combustible materials are not part of the ANSI Z21.1 scope and are not certi ed by CSA. Clearances of less than 12" (305 mm) must be approved by the local codes and/or by the local authority having jurisdiction. NOTE: A 36-inch minimum clearance is required between the top of the cooking surface and the bottom of an unprotected cabinet. A 30-inch clearance can be used when the bottom of the wood or metal cabinet is protected by not less than 1/4 inch of a flame retardant material covered with not less than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick stainless steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper. ELECTRICAL AND GAS LOCATIONS The gas and electrical supply must be located in an area that is accessible without requiring removal of the rangetop. The appliance electrical power cord and gas pipe connection are located on the left rear underside of the rangetop. The junction box must be located within 3 feet (~900 mm) of the rangetop connection. NATURAL GAS REQUIREMENTS: Inlet Connection: 1/2" NPT (min. 3/4" dia. flex line) Supply Pressure: 6" min. to 14" max. water column (14.9 mb to 34.9 mb) Manifold Pressure: 5" water column (12.5 mb) PROPANE GAS REQUIREMENTS: Inlet Connection: 1/2" NPT (min. 3/4" dia. flex line) Supply Pressure: 11" min. to 14" max. water column (27.4 mb to 34.9 mb) Manifold Pressure: 10" water column (24.9 mb) 71 BPRUOILFT-EINSSOIOVNEANLS RANGETOPS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

1.800.735.4328
|
THERMADOR.COM
BUILT-IN OVENS
71
PROFESSIONAL RANGETOPS
48-INCH
PCG486GD
48-INCH RANGETOP AND CUTOUT DIMENSIONS
INSTALLATION OPTIONS
To ensure professional results, the cabinet and
countertop openings should be prepared by a
qualified cabinet worker. The rangetop can be installed
in various positions with the front either flush or
projecting, depending on the countertop‘s depth.
The rangetop is designed to hang from the countertop
by its side flanges. The countertop however, must be
strong enough to support the rangetop. It may be
necessary to add a supporting cleat along each side
or a 2" x 4" corner brace. Another alternative would
be to construct a deck to set the rangetop on. Consult
with the installation manual packed with the product
for complete details before installing.
ABOVE A WARMING DRAWER
Thermador Professional
®
Rangetops may be installed
above a Thermador Warming Drawer to create a
convenient cooking center. A minimum 2
3
/
4
" clearance
is required between the bottom of the rangetop and
the top of the warming drawer. Refer to the warming
drawer section for additional specifications.
BACKGUARDS
When using the Flush Island Trim, Thermador
recommends a minimum 12" (305 mm) rear clearance
to a combustible surface (see Figure 1, Cabinet
Clearances). Clearances from non-combustible
materials are not part of the ANSI Z21.1 scope and are
not certified by CSA. Clearances of less than 12" (305
mm) must be approved by the local codes and / or by
the local authority having jurisdiction.
NATURAL GAS OR LP
Thermador Professional
®
Rangetops are shipped by
the factory to operate on natural gas. They must be
converted for use with propane. Verify the type of gas
being used at the installation site matches the type
of gas used by the appliance. If the location / job site
requires conversion from natural gas to propane (LP),
order PALPKITHC. Field conversion must be done by
qualified service personnel only. Please refer to the
LP Conversion Instructions packed with product for
further information.
IMPORTANT
We strongly recommend that a Thermador
Professional Wall or Island Hood or Custom Insert be
installed with all Thermador Professional
®
Rangetops.
Downdraft ventilation should not be used. Do not
install a microwave-hood combination above the
rangetop, as these types of units do not provide
the proper ventilation and are not suitable for use
with Thermador Professional
®
Rangetops.
Refer to
the ventilation section or www.Thermador.com for a
complete selection of Professional ventilation options,
blowers, and accessories.
ELECTRICAL AND GAS LOCATIONS
The gas and electrical supply must be located in an area that is accessible
without requiring removal of the rangetop. The appliance electrical power
cord and gas pipe connection are located on the left rear underside of
the rangetop.
The junction box must be located within 3 feet (~900 mm) of the
rangetop connection.
PROFESSIONAL RANGETOPS
NATURAL GAS
REQUIREMENTS:
Inlet Connection:
1
/
2
" NPT
(min.
3
/
4
" dia. flex line)
Supply Pressure: 6" min.
to 14" max. water column
(14.9 mb to 34.9 mb)
Manifold Pressure: 5"
water column (12.5 mb)
PROPANE GAS
REQUIREMENTS:
Inlet Connection:
1
/
2
" NPT
(min.
3
/
4
" dia. flex line)
Supply Pressure: 11" min.
to 14" max. water column
(27.4 mb to 34.9 mb)
Manifold Pressure: 10"
water column (24.9 mb)
NOTE:
A 36-inch minimum clearance is required between the top of the
cooking surface and the bottom of an unprotected cabinet. A 30-inch
clearance can be used when the bottom of the wood or metal cabinet is
protected by not less than
1
/
4
inch of a flame retardant material covered with
not less than No. 28 MSG sheet steel, 0.015 inch (0.4 mm) thick stainless
steel, 0.024 inch (0.6 mm) aluminum, or 0.020 inch (0.5 mm) thick copper.
as defined in the “National Fuel Gas Code” (ANSI Z223.1,
Current Edition). Clearances from non-combustible materials
are not part of the ANSI Z21.1 scope and are not certified by
CSA. Clearances of less than 12” (305 mm) must be approved
by the local codes and/or by the local authority having
jurisdiction.
PROFESSIONAL RANGETOPS
1.800.735.4328
|
THERMADOR.COM
71