Thermador PCG486NL Design Guide - Page 4

Planning Information

Page 4 highlights

PROFESSIONAL RANGETOPS PROFESSIONAL RANGETOPS PLANNING INFORMATION MODEL OPTIONS There are three sizes of Thermador Professional® Rangetops to choose from - 30-inch, 36-inch and 48-inch. 36-inch rangetops are available with two choices of rangetop con gurations. Every model ships standard with an Island Trim. Every model is LP convertible by ordering PALPKITHC. Be sure to reference the correct model information in this design guide. INSTALLATION CONSIDERATIONS The information in this design guide provides key features, product dimensions, cutouts and installation speci cations. Before installing a Thermador Professional® Rangetop, be sure to verify the cutout dimensions and electrical / gas connections. Also, always consult with the installation manual packed with the product for complete details before installing. Thermador Professional® Rangetops may be installed above a Thermador Warming Drawer to create a convenient cooking center. A minimum 2 3/4" clearance is required between the bottom of the rangetop and the top of the warming drawer. Refer to the warming drawer section for additional speci cations. ELECTRICAL AND GAS SPECIFICATIONS Be sure your appliance is properly installed and grounded by a quali ed technician. Installation, electrical and gas connections, and grounding must comply with all applicable local codes. Thermador Professional® Rangetops are equipped with a 3-wire plug and are designed to be connected to a 120V AC, 60 Hz, single-phase power supply. A dedicated circuit breaker is required. MODEL PCG304G PCG364GD PCG366G PCG486GD REQUIRED CIRCUIT BREAKER 120V AC, 60Hz 15 Amp 15 Amp 15 Amp 15 Amp GAS REQUIREMENTS AND HOOKUP Rangetops are shipped by the factory to operate on natural gas. They must be converted for use with propane. Verify that the type of gas being used at the installation site matches the type of gas used by the appliance. If the location / job site requires conversion from natural gas to propane (LP), order PALPKITHC. Field conversion must be done by quali ed service personnel only. Please refer to the LP Conversion Instructions for further information. A manual gas shut-off valve must be installed external to the appliance, in a location accessible from the front, for the purpose of shutting off the gas supply. The supply line must not interfere with the back of the unit. WARRANTY Limited warranty parts and labor (2 year) See page 310 for additional warranty details. 1.800.735.4328 | THERMADOR.COM VENTILATION REQUIREMENTS We strongly recommend that a Thermador Professional® Wall or Island Hood or Custom Insert be installed with all Thermador Professional® Rangetops. Downdraft ventilation should not be used. Do not install a microwave-hood combination above the rangetop, as these types of units do not provide the proper ventilation and are not suitable for use with Thermador Professional® Rangetops. For high output gas cooktops or rangetops (60,000 BTU or greater), the minimum of one (1) CFM of ventilation per 100 BTU is recommended. If the cooktop or rangetop has a grill or griddle, add 150 CFM to the estimated blower capacity. Additional blower capacity may be required for longer duct runs. The following table indicates the ventilation hood options and blower capacity guidelines that are recommended for use with Thermador Professional® Rangetops. Refer to the Ventilation section or www.Thermador. com for a complete selection of Professional ventilation options, blowers, and accessories. WIDTH CONFIGURATION VENTILATION OPTIONS 30" 4 Burners 30" or 36" Pro Wall Hood 30" or 36" Custom Insert with optional blower 42" Island Hood with optional blower 36" 4 Burners w/Grill or Griddle 6 Burners 36" or 42" Pro Wall Hood 36" Custom Insert with optional blower 42" or 48" Island Hood with optional blower 48" 6 Burners w/Grill or Griddle 48" or 54" Pro Wall Hood 48" Custom Insert with optional blower 54" Island Hood with optional blower IMPORTANT VENTILATION NOTES: • Due to high surface temperature output, the HPWB Professional Series Wall Hoods or the Professional Custom Inserts are recommended ventilation solutions for these rangetops. The PH Professional Series Wall Hoods are also a viable option. • For wall installations, the hood width must, at a minimum, equal the nominal width of the appliance cooking surface. Where space permits, a hood larger in width than the cooking surface may be desirable for improved ventilation performance. • For island installations the hood width should, at a minimum, overhang the appliance cooking surface by 3" on each side. • Due to the high heat capability of these rangetops, particular attention should be paid to the hood and duct work installation to assure it meets local building codes. • For best smoke elimination, the lower edge of the hood should be installed 30" above the appliance cooking surface. • If the hood contains any combustible materials (i.e., a wood covering), it must be 36"or greater distance above the cooking surface. Thermador Professional® Rangetops are CSA approved. CERTIFIED DESIGN C E R TIF D IE 63

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

PROFESSIONAL RANGETOPS
1.800.735.4328
|
THERMADOR.COM
63
PROFESSIONAL RANGETOPS
PLANNING INFORMATION
GAS REQUIREMENTS AND HOOKUP
Rangetops are shipped by the factory to operate
on natural gas. They must be converted for use with
propane. Verify that the type of gas being used at the
installation site matches the type of gas used by the
appliance. If the location / job site requires conversion
from natural gas to propane (LP), order PALPKITHC. Field
conversion must be done by qualified service personnel
only. Please refer to the LP Conversion Instructions for
further information.
A manual gas shut-off valve must be installed external to
the appliance, in a location accessible from the front, for
the purpose of shutting off the gas supply. The supply
line must not interfere with the back of the unit.
WARRANTY
Limited warranty parts and labor (2 year)
See page 310 for additional warranty details.
VENTILATION REQUIREMENTS
We strongly recommend that a Thermador Professional
®
Wall or Island Hood
or Custom Insert be installed with all Thermador Professional
®
Rangetops.
Downdraft ventilation should not be used. Do not install a microwave-hood
combination above the rangetop, as these types of units do not provide
the proper ventilation and are not suitable for use with Thermador
Professional
®
Rangetops.
For high output gas cooktops or rangetops (60,000 BTU or greater), the
minimum of one (1) CFM of ventilation per 100 BTU is recommended. If
the cooktop or rangetop has a grill or griddle, add 150 CFM to the estimated
blower capacity. Additional blower capacity may be required for longer
duct runs.
The following table indicates the ventilation hood options and blower
capacity guidelines that are recommended for use with Thermador
Professional
®
Rangetops. Refer to the Ventilation section or www.Thermador.
com for a complete selection of Professional ventilation options, blowers,
and accessories.
IMPORTANT VENTILATION NOTES:
Due to high surface temperature output, the HPWB Professional Series Wall
Hoods or the Professional Custom Inserts are recommended ventilation
solutions for these rangetops. The PH Professional Series Wall Hoods are
also a viable option.
For wall installations, the hood width must, at a minimum, equal the
nominal width of the appliance cooking surface. Where space permits,
a hood larger in width than the cooking surface may be desirable for
improved ventilation performance.
For island installations the hood width should, at a minimum, overhang the
appliance cooking surface by 3" on each side.
Due to the high heat capability of these rangetops, particular attention
should be paid to the hood and duct work installation to assure it meets
local building codes.
For best smoke elimination, the lower edge of the hood should be installed
30" above the appliance cooking surface.
If the hood contains any combustible materials (i.e., a wood covering), it
must be 36"or greater distance above the cooking surface.
Thermador Professional
®
Rangetops are CSA approved.
MODEL
REQUIRED CIRCUIT BREAKER
120V AC, 60Hz
PCG304G
15 Amp
PCG364GD
15 Amp
PCG366G
15 Amp
PCG486GD
15 Amp
WIDTH
CONFIGURATION
VENTILATION OPTIONS
30"
4
Burners
30" or 36" Pro Wall Hood
30" or 36" Custom Insert with
optional blower
42" Island Hood with optional blower
36"
4
Burners w/Grill
or Griddle
6 Burners
36" or 42" Pro Wall Hood
36" Custom Insert with
optional blower
42" or 48" Island Hood with
optional blower
48"
6
Burners w/Grill
or Griddle
48" or 54" Pro Wall Hood
48" Custom Insert with
optional blower
54" Island Hood with optional blower
MODEL OPTIONS
There are three sizes of Thermador Professional
®
Rangetops to choose from — 30-inch, 36-inch and
48-inch. 36-inch rangetops are available with two choices
of rangetop configurations. Every model ships standard
with an Island Trim. Every model is LP convertible by
ordering PALPKITHC. Be sure to reference the correct
model information in this design guide.
INSTALLATION CONSIDERATIONS
The information in this design guide provides key
features, product dimensions, cutouts and installation
specifications. Before installing a Thermador
Professional
®
Rangetop, be sure to verify the cutout
dimensions and electrical / gas connections. Also, always
consult with the installation manual packed with the
product for complete details before installing.
Thermador Professional
®
Rangetops may be installed
above a Thermador Warming Drawer to create a
convenient cooking center. A minimum 2
3
/
4
" clearance
is required between the bottom of the rangetop and the
top of the warming drawer. Refer to the warming drawer
section for additional specifications.
ELECTRICAL AND GAS SPECIFICATIONS
Be sure your appliance is properly installed and
grounded by a qualified technician. Installation, electrical
and gas connections, and grounding must comply with
all applicable local codes.
Thermador Professional
®
Rangetops are equipped with
a 3-wire plug and are designed to be connected to a
120V AC, 60 Hz, single-phase power supply. A dedicated
circuit breaker is required.